Sharp MX-4100N Service Manual page 269

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

: Oct. 24 2008
1
Mode
Item/Display
PR600/
A
LASER POWER MIDDLE (K1)
1
FAX
B
LASER POWER MIDDLE (K2)
C
LASER POWER MIDDLE (C1)
D
LASER POWER MIDDLE (C2)
E
LASER POWER MIDDLE (M1)
F
LASER POWER MIDDLE (M2)
G
LASER POWER MIDDLE (Y1)
H
LASER POWER MIDDLE (Y2)
I
LASER POWER LOW (K1)
J
LASER POWER LOW (K2)
K
LASER POWER LOW (C1)
L
LASER POWER LOW (C2)
M
LASER POWER LOW (M1)
N
LASER POWER LOW (M2)
O
LASER POWER LOW (Y1)
P
LASER POWER LOW (Y2)
Q
LASER POWER MIDDLE (BW1)
R
LASER POWER MIDDLE (BW2)
S
LASER POWER LOW (BW1)
T
LASER POWER LOW (BW2)
U
LASER DUTY MIDDLE (K)
V
LASER DUTY MIDDLE (C)
W
LASER DUTY MIDDLE (M)
X
LASER DUTY MIDDLE (Y)
Y
LASER DUTY LOW (K)
Z
LASER DUTY LOW (C)
AA
LASER DUTY LOW (M)
AB
LASER DUTY LOW (Y)
AC
LASER DUTY MIDDLE (BW)
AD
LASER DUTY LOW (BW)
PR1200
A
LASER POWER MIDDLE (K1)
B
LASER POWER MIDDLE (K2)
C
LASER POWER MIDDLE (C1)
D
LASER POWER MIDDLE (C2)
E
LASER POWER MIDDLE (M1)
F
LASER POWER MIDDLE (M2)
G
LASER POWER MIDDLE (Y1)
H
LASER POWER MIDDLE (Y2)
I
LASER POWER LOW (K1)
J
LASER POWER LOW (K2)
K
LASER POWER LOW (C1)
L
LASER POWER LOW (C2)
M
LASER POWER LOW (M1)
N
LASER POWER LOW (M2)
O
LASER POWER LOW (Y1)
P
LASER POWER LOW (Y2)
Q
LASER POWER MIDDLE (BW1)
R
LASER POWER MIDDLE (BW2)
S
LASER POWER LOW (BW1)
T
LASER POWER LOW (BW2)
U
LASER DUTY MIDDLE (K)
V
LASER DUTY MIDDLE (C)
W
LASER DUTY MIDDLE (M)
X
LASER DUTY MIDDLE (Y)
Y
LASER DUTY LOW (K)
Z
LASER DUTY LOW (C)
AA
LASER DUTY LOW (M)
AB
LASER DUTY LOW (Y)
AC
LASER DUTY MIDDLE (BW)
AD
LASER DUTY LOW (BW)
Content
Used to set the laser power (Middle speed/K1)
Used to set the laser power (Middle speed/K2)
Used to set the laser power (Middle speed/C1)
Used to set the laser power (Middle speed/C2)
Used to set the laser power (Middle speed/M1)
Used to set the laser power (Middle speed/M2)
Used to set the laser power (Middle speed/Y1)
Used to set the laser power (Middle speed/Y2)
Used to set the laser power (Low speed/K1)
Used to set the laser power (Low speed/K2)
Used to set the laser power (Low speed/C1)
Used to set the laser power (Low speed/C2)
Used to set the laser power (Low speed/M1)
Used to set the laser power (Low speed/M2)
Used to set the laser power (Low speed/Y1)
Used to set the laser power (Low speed/Y2)
Used to set the laser power (Middle speed/BW1)
Used to set the laser power (Middle speed/BW2)
Used to set the laser power (Low speed/BW1)
Used to set the laser power (Low speed/BW2)
Laser DUTY select middle speed (K)
Laser DUTY select middle speed (C)
Laser DUTY select middle speed (M)
Laser DUTY select middle speed (Y)
Laser DUTY select low speed (K)
Laser DUTY select low speed (C)
Laser DUTY select low speed (M)
Laser DUTY select low speed (Y)
Laser DUTY select middle speed (BW)
Laser DUTY select low speed (BW)
Used to set the laser power (Middle speed/K1)
Used to set the laser power (Middle speed/K2)
Used to set the laser power (Middle speed/C1)
Used to set the laser power (Middle speed/C2)
Used to set the laser power (Middle speed/M1)
Used to set the laser power (Middle speed/M2)
Used to set the laser power (Middle speed/Y1)
Used to set the laser power (Middle speed/Y2)
Used to set the laser power (Low speed/K1)
Used to set the laser power (Low speed/K2)
Used to set the laser power (Low speed/C1)
Used to set the laser power (Low speed/C2)
Used to set the laser power (Low speed/M1)
Used to set the laser power (Low speed/M2)
Used to set the laser power (Low speed/Y1)
Used to set the laser power (Low speed/Y2)
Used to set the laser power (Middle speed/BW1)
Used to set the laser power (Middle speed/BW2)
Used to set the laser power (Low speed/BW1)
Used to set the laser power (Low speed/BW2)
Laser DUTY select middle speed (K)
Laser DUTY select middle speed (C)
Laser DUTY select middle speed (M)
Laser DUTY select middle speed (Y)
Laser DUTY select low speed (K)
Laser DUTY select low speed (C)
Laser DUTY select low speed (M)
Laser DUTY select low speed (Y)
Laser DUTY select middle speed (BW)
Laser DUTY select low speed (BW)
MX-5001N SIMULATION 6 – 122
De-fault value
Setting
Destination
41-sheet
50-sheet
range
machine
machine
0 - 255
133
165
0 - 255
133
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
133
165
0 - 255
133
165
0 - 255
142
142
0 - 255
142
142
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
133
165
0 - 255
133
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
146
165
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
142
142
0 - 255
133
165
0 - 255
133
165
0 - 255
142
142
0 - 255
142
142
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
0 - 255
0
0
linkage