Sharp MX-4100N Service Manual page 218

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

44-28
Purpose
Adjustment/Setup
Function (Purpose) Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
1)
Select a target item of setting with [↑] [↓] key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
Mode
Item/Display
Process control
A
INITIAL
Enable/Disable
setting
B
SW ON
C
TIME
D
HUM_LIMIT
E
HUM
YES
When warm-up after clearing the
counter of the OPC drum and the
NO
developer unit
When supplying the power (when
clearing shut-off.)
After passing the specified time from
leaving READY continuously (Time
can be changed by INTERVAL TIME)
HUM judgment is made when turning
ON the power and after passing
TIME.
The temperature and humidity in side
the machine are monitored only
during a job for every 2hours (set by
item N). When the changes in the
temperature and the humidity are
greater than the specified level (the
set value of item O) in comparison
with the previous process control.
MX-5001N SIMULATION 6 – 71
Content
Enable
Disable
Color process
control Enable
Process control
Disable
BK process control
Enable
Pixel count
judgment
(Judgement is
based on the setting
value of item K, L.)
Color process
control Enable
Process control
Disable
BK process control
Enable
Pixel count
judgment
(Judgement is
based on the setting
value of item K, L.)
Color process
control Enable
Process control
Disable
BK process control
Enable
Color process
control Enable
Process control
Disable
BK process control
Enable
Default
Setting range
value
0 - 1
0
0
1
0 - 3
0
3
1
2
3
0 - 3
0
3
1
2
3
0 - 2
0
0
1
2
0 - 2
0
0
1
2

Advertisement