3)
Disengage the hook of the lower separation pawl spring (B)
from the rib, and remove four lower separation pawls (A) and
four lower separation pawls springs (B).
Maintenance: Replace at every 300K.
A
2
B
4)
Remove the screw, and remove the fusing rear PG.
1
MX-5001N MAINTENANCE 8 – 30
5)
Lift the lead edge (C) of the upper separation pawl (A) and
remove the upper separation spring (B) and the upper separa-
tion pawl (A).
D
A
NOTE: The upper separation adjustment plate (D) is factory
adjusted. Do Not touch screws and re-adjust the plate.
6)
Remove the screw, and remove the upper lamp holder F.
Disconnect the lamp connector on the rear side, and remove
the upper lamp harness from the upper lamp holder R.
NOTE: Put the upper heater lamp harness on the bent section
beside the upper lamp holder F and pass through the
clamp.
C
B