: Oct. 24 2008
1
50-24
Purpose
(This simulation is normally not used in the
market.)
Function (Purpose) Used to display the detail data of SIM 44-2,
50-20, 21 and 22.
Section
Operation/Procedure
NOTE: This simulation is mainly used by the technical division, and
is not necessary for the market.
Item
classific
Display
Item content
ation
Regist-
REG_EXE_CNT
Number of
ration
executions of
adjust-
the registration
ment
adjustment
status
(Auto
check
execution)
REG_SUC_CNT
Number of
success of the
registration
adjustment
(Auto
execution)
REG_CNT
Registration
adjustment
registration
counter
REG_M_F
Calculated
(VALUE)
correction
amount in the
main scan
direction F in
the auto
registration
adjustment
REG_M_R
Calculated
(VALUE)
correction
amount in the
main scan
direction R in
the auto
registration
adjustment
REG_SUB
Calculated
(VALUE)
correction
amount in the
sub scan
direction in the
automatic
registration
adjustment
REG_M_F (DIF)
Registration
value
correction
amount from
the previous
time, main
scan F
REG_M_R (DIF)
Registration
value
correction
amount from
the previous
time, main
scan R
REG_SUB (DIF)
Registration
value
correction
amount from
the previous
time, sub scan
Phase
1
adjust-
ment
status
check
Setting
Related
range
SIM
0 - 99999999
50-22
0 - 99999999
50-22
0 - 99999999
-
1.0 - 199.0
50-22
(±0.1 unit)
1.0 - 199.0
50-22
(±0.1 unit)
Sensor
calibra-
tion
status
1.0 - 199.0
50-22
check
(±0.1 unit)
-199.0 -
50-20,
199.0 (±0.1
22
unit)
-199.0 -
50-20,
199.0 (±0.1
22
unit)
Sampling
status
check (1)
-199.0 -
50-21,
199.0 (±0.1
22
unit)
MX-5001N SIMULATION 6 – 107
Item
classific
Display
Item content
ation
PHASE_ADJ (C)
Phase
(50-sheet
adjustment
machine)
(1: This time
value,
2: Previous
time value)
PHASE_ADJ
Phase
(M)
adjustment
(50-sheet
(1: This time
machine)
value,
2: Previous
time value)
PHASE_ADJ (Y)
Phase
(50-sheet
adjustment
machine)
(1: This time
value,
2: Previous
time value)
PHASE_ADJ
Phase
(41-sheet
adjustment
machine)
(1: This time
value,
2: Previous
time value)
PHASE_STATE
Phase state
(1: This time
value,
2: Previous
time value)
PHASE_LEVEL
Phase
deflection level
(before
weighting)
PHASE
Phase
_WEIGHT
deflection level
(after
weighting)
(1: This time
value,
2: Previous
time value)
REG_LED (F)
Registration
sensor current
light emitting
value F
REG_LED (R)
Registration
sensor current
light emitting
value R
REG_V (F)
Registration
sensor current
light receiving
value F
REG_V (R)
Registration
sensor current
light receiving
value R
REG_DARK (F)
Registration
sensor dark
potential F
REG_DARK (R)
Registration
sensor dark
potential R
START_SUB
Sampling start
(F)_U
value Sub scan
F (Rising)
START_SUB
Sampling start
(F)_D
value Sub scan
F (Falling)
START_SUB
Sampling start
(R)_U
value Sub scan
R (Rising)
START_SUB
Sampling start
(R)_D
value Sub scan
R (Falling)
Setting
Related
range
SIM
1 - 8
50-22
1 - 8
50-22
1 - 8
50-22
1 - 8
50-22
1 - 8
50-22
0-99.9
50-22
(±0.1 unit)
0-99.9
50-22
(±0.1 unit)
1 - 255
44-02,
70-11,
50-22
1 - 255
44-02,
70-11,
50-22
0 - 255
44-02,
70-11,
50-22
0 - 255
44-02,
70-11,
50-22
0 - 255
44-02,
70-11,
50-22
0 - 255
44-02,
70-11,
50-22
-300.00 -
50-22
300.00
(±0.01 unit)
-300.00 -
50-22
300.00
(±0.01 unit)
-300.00 -
50-22
300.00
(±0.01 unit)
-300.00 -
50-22
300.00
(±0.01 unit)