H4-30
Thermistor input circuit trouble
(TH_UM)
Trouble content
Detail
PCU
Cause
The values of TH_UM_AD1 and TH_UM_AD2 do not
exceed the specified value (50 counts in AD value)
within the specified time from turning ON the
HL_UM.
Thermistor trouble.
Heater lamp trouble.
PCU PWB trouble
Thermostat trouble.
Connector, harness connection trouble.
Power unit trouble.
Interlock switch trouble
Check & Remedy
Replace the thermistor.
Replace the heater lamp.
Replace the PCU PWB.
Replace the thermostat.
Check connection of the connector and the harness.
Replace the power unit.
Replace the interlock switch.
Use SIM5-2 to check the flashing operation of the
heater lamp.
Use SIM14 to cancel the trouble.
H5-01
5 times continuous POD1 not-reach
jam
Trouble content
Detail
PCU
Cause
A fusing jam is not canceled completely. (A jam
paper remains.)
POD1 sensor trouble.
Fusing unit installation trouble.
Connector, harness connection trouble.
PCU PWB trouble
Check & Remedy
Replace the POD1 sensor.
Check the installing position of the fusing unit.
Replace the fusing unit.
Check connection of the connector and the harness.
Replace the PCU PWB.
Use SIM14 to cancel the trouble.
H7-10
Recovery error from low fuser temp.
(TH_UM_AD2)
Trouble content
Detail
PCU
Cause
The fusing temperature does not reach the specified
level within the specified time from stopping a job
due to fall in the fusing temperature.
Thermistor trouble.
Heater lamp trouble.
PCU PWB trouble
Thermostat trouble.
Connector, harness connection trouble.
Power unit trouble.
Interlock switch trouble.
Check & Remedy
Replace the thermistor.
Replace the heater lamp.
Replace the PCU PWB.
Replace the thermostat.
Check connection of the connector and the harness.
Replace the power unit.
Replace the interlock switch.
Use SIM5-2 to check the flashing operation of the
heater lamp.
MX-5001N SELF DIAG AND TROUBLE CODE 7 – 20
H7-11
Recovery error from low fuser temp.
(TH_LM)
Trouble content
Detail
PCU
Cause
The fusing temperature does not reach the specified
level within the specified time from stopping a job
due to fall in the fusing temperature.
Thermistor trouble.
Heater lamp trouble.
PCU PWB trouble
Thermostat trouble.
Connector, harness connection trouble.
Power unit trouble.
Interlock switch trouble.
Check & Remedy
Replace the thermistor.
Replace the heater lamp.
Replace the PCU PWB.
Replace the thermostat.
Check connection of the connector and the harness.
Replace the power unit.
Replace the interlock switch.
Use SIM5-2 to check the flashing operation of the
heater lamp.
H7-12
Recovery error from low fuser temp.
(TH_US)
Trouble content
Detail
PCU
Cause
The fusing temperature does not reach the specified
level within the specified time from stopping a job
due to fall in the fusing temperature.
Thermistor trouble.
Heater lamp trouble.
PCU PWB trouble
Thermostat trouble.
Connector, harness connection trouble.
Power unit trouble.
Interlock switch trouble.
Check & Remedy
Replace the thermistor.
Replace the heater lamp.
Replace the PCU PWB.
Replace the thermostat.
Check connection of the connector and the harness.
Replace the power unit.
Replace the interlock switch.
Use SIM5-2 to check the flashing operation of the
heater lamp.