Sharp MX-4100N Service Manual page 216

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

Item/Display
Content
ENV VO
Environment
Control voltage
correction
correction value for
control
the high humidity
voltage
environment
Item/Display
Content
AUTO DEVE
Area in the
Humidity area
AREA
auto
display in the
development
automatic developer
adjustment
adjustment
AREA
Current area
Current humidity
area display
44-21
Purpose
Adjustment/Setup
Function (Purpose) Used to set the half tone process control
target.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The half tone process control target is set and the operation data
are displayed.
Display
COMPLETE
ERROR COLOR SENSOR
ADJUSTMENT
ERROR BLACK SENSOR
ADJUSTMENT
[YMCK]
OTHER
Setting
Default
range
value
-127 -
0
127
Setting
Default
range
value
1 - 14
8
Content
Normal complete
Color image density sensor
sensitivity adjustment error
Black image density sensor
sensitivity adjustment error
High density process control error
[YMCK]
Other errors
MX-5001N SIMULATION 6 – 69
44-22
Purpose
Operation data display
Function (Purpose) Used to display the toner patch density
level in the half tone process control opera-
tion.
Section
Process
Operation/Procedure
1)
Select the display mode with [1ST STEP],[2ND STEP] key.
The toner patch density level made in the half tone process
control operation is displayed.
Item/Display
ID_n
Patch data display (n=1-16)
BASE1
Belt substrate data (START)
BASE5
Belt substrate data (LAST)
44-24
Purpose
Operation data display
Function (Purpose) Used to display the correction target and
the correction level in the half tone process
control operation.
Section
Process
Operation/Procedure
1)
Select the display category with [NEXT] key.
2)
Select a target adjustment color with [K] [C] [M] [Y] key.
Category
Item/Display
Coefficient
[EX-LOW]
[LOW]
[CONNECT]
[MID]
[HIGH]
[CONNECT POINT]
Reference
[SENSOR_TARGET]
value
Correction
[S_VALUE]
value
Content
Content
Coefficient of the
approximation formula of
the minimum density
Coefficient of the
approximation formula of
the low density
Coefficient of the
approximation formula of
when connecting the low
density and the medium
density
Coefficient of the
approximation formula of
the medium density
Coefficient of the
approximation formula of
the high density
Each density section
connection output ratio
Half tone process control
reference value
Half tone process control
correction value

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-5000nMx-4101nMx-5001n

Table of Contents