: Oct. 24 2008
1
[50-sheet machine]
1
Item/Display
A
HL_UM READY HH
B
HL_LM READY HH
C
HL_E READY HH
D
HL_UM PLAIN BW HH
E
HL_LM PLAIN BW HH
F
HL_E PLAIN BW HH
G
HL_UM PLAIN CL HH
H
HL_LM PLAIN CL HH
I
HL_E PLAIN CL HH
J
WARMUP FUMON HL_E T HH
K
WARMUP FUMOFF T HH
L
WARMUP END TIME HH
M
HL_UM HEAVY HH
N
HL_LM HEAVY HH
O
HL_E HEAVY HH
P
HL_UM OHP HH
Q
HL_LM OHP HH
R
HL_E OHP HH
S
HL_UM ENVELOPE HH
T
HL_LM ENVELOPE HH
U
HL_E ENVELOPE HH
V
HL_UM GLOSS HH
W
HL_LM GLOSS HH
X
HL_E GLOSS HH
Y
HL_UM E-STAR HH
Z
HL_E E-STAR HH
AA
PRE-JOB HH
AB
HL_LM E-STAR HH
AC
HL UM HEAVY2 CL HH
AD
HL LM HEAVY2 CL HH
AE
HL E HEAVY2 CL HH
AF
HL_UM WARMUP_120L HH
AG
HL_LM WARMUP_120L HH
AH
HL_E WARMUP_120L HH
AI
LO_WARMUP_TIME_HH
Content
Correction value for TH_UM set value in Ready standby
under HH environment
Correction value for TH_LM set value in Ready standby
under HH environment
Correction value for TH_E set value in Ready standby
under HH environment
Correction value for Black-White plain paper TH_UM set
value under HH environment
Correction value for Black-White plain paper TH_LM set
value under HH environment
Correction value for Black-White plain paper TH_E set
value under HH environment
Correction value for Color plain paper TH_UM set value
under HH environment
Correction value for Color plain paper TH_LM set value
under HH environment
Correction value for Color plain paper TH_E set value under
HH environment
Correction value for fusing motor pre-rotation start TH_E set
value under HH environment
Fusing motor prior rotation completion time under HH
environment
Correction value for warm-up complete time under HH
environment
Correction value for heavy paper TH_UM set value under
HH environment
Correction value for heavy paper TH_LM set value under
HH environment
Correction value for heavy paper TH_E set value under HH
environment
Correction value for OHP TH_UM set value under HH
environment
Correction value for OHP TH_LM set value under HH
environment
Correction value for OHP TH_E set value under HH
environment
Correction value for envelope TH_UM set value under HH
environment
Correction value for envelope TH_LM set value under HH
environment
Correction value for envelope TH_E set value under HH
environment
Correction value for glossy paper TH_UM set value under
HH environment
Correction value for glossy paper TH_LM set value under
HH environment
Correction value for glossy paper TH_E set value under HH
environment
Correction value for preheating TH_UM set value under HH
environment
Correction value for preheating TH_E set value under HH
environment
Correction value for resetting from preheating
TH_UM+TH_E set value under HH environment
Correction value for preheating TH_LM set value under HH
environment
Correction value for heavy paper 2 TH_UM set value under
HH environment
Correction value for heavy paper 2 TH_LM set value under
HH environment
Correction value for heavy paper 2 TH_E set value under
HH environment
Correction value for TH_UM set value in WarmUp at 120°C
or below under HH environment
Correction value for TH_LM set value in WarmUp at 120°C
or below under HH environment
Correction value for TH_E set value in WarmUp at 120°C or
below under HH environment
Correction value for AF-AH applying time (timer from Ready
complete) under HH environment
MX-5001N SIMULATION 6 – 56
Setting
Default value
range
Group 1
Group 2
Group 3
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
1 - 99
50
50
Destination
linkage
(NOTE)
50
50
50
50
50
50
50
50
50
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–
50
–