Sharp MX-4100N Service Manual page 219

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

Mode
Item/Display
Process con-
F
REV1
trol Enable/
Disable set-
ting
G
REV2_BK
H
REV2_CL
I
REFRESH
MODE(*1)
Process control
J
DAY
conditions
setting
K
PIX_RATIO_BK
L
PIX_RATIO_CL
M
INTERVAL TIME
N
HUM HOUR
O
HUM_DIF
P
BK_RATIO
Q
M_RATIO
R
COLOR BORDER
S
BK ONLY
T
HT_DIF
Registration
U
RG_ON_SYNC
adjustment
setting
V
RG_TEMP_TIMER
W
RG_PERM_TIMER
X
RG_HOUR_TIMER
Secondary
Y
2TRAN_CLEAN_TIME1
transfer
cleaning setting
Z
2TRAN_CLEAN_TIME2
AA
2TRAN_CLEAN_TIME3
*1: When REFRESH MODE setting is enabled (0), the menu of the
user process control execution button is displayed on the user sys-
tem setting menu.
When the color balance or the density change is not within the
allowable range, the user can perform the process control manually
and forcibly. However, toner is consumed grater than as usual. This
point must be explained to the user clearly.
YES
The accumulated traveling distance
of BK or M position OPC unit reaches
NO
the specified level after turning the
power.
YES
The accumulated traveling distance
of BK position OPC drum unit
NO
reaches the specified level from
execution of the previous density
correction.
YES
The accumulated traveling distance
of M position OPC drum unit reaches
NO
the specified level from execution of
the previous density correction.
YES
Select of YES/NO of the manual
process control key with key
operation
NO
When the next warm-up if there is no
color job after a color job after
passing the specified days from
execution of the previous color
process control
Magnification ratio setting (%) of the BK toner count specified
value entry of 100 corresponds to 1k of A4 5% print.
Magnification ratio setting (%) of the color (CMY) toner count
specified value entry of 100 corresponds to 1k of A4 5% print.
Passing time setting of "TIME"(h: hour)
Interval setting of the temperature and humidity monitoring
time of "HUM" (h: hour)
Area difference specified value when compared with the
execution of the previous process control of "HUM"
Magnification ratio setting (%) of the specified value of the
BK position OPC drum traveling distance of "REV2_BK"
Magnification ratio setting (%) of the M position OPC drum
traveling distance of "REV2_CL"
Magnification ratio setting (%) of the
M position OPC drum traveling
distance when executing the BK
process control
Disable/Enable setting and setting of
the number of repetition of the BK
process control when monochrome
print is continued.
Bias change difference value used for judgment of HT
process control
CL
Select of synchronous/asynchronous of the power ON
process control
ALL
CL/BK
Execution timing setting after turning ON the power
Span setting from execution Disable to Enable
Span setting of timer execution
Secondary transfer cleaning process time judgment
threshold value 1
Secondary transfer cleaning process time judgment
threshold value 2
Secondary transfer cleaning process time judgment
threshold value 3
MX-5001N SIMULATION 6 – 72
Content
Enable
Inhibit
Enable
Inhibit
Enable
Inhibit
Key operation
display
Key operation NO
display
Disable of the
specified days
judgment
1 - 999 days passing
BK process control
is executed without
judgment of ratio of
the M OPC drum
traveling distance.
1 - 999(%)
Enable 5 time
Disable 1-5 times
Inhibit
Default
Setting range
value
0 - 1
0
0
1
0 - 1
0
0
1
0 - 1
0
0
1
0 - 1
0
1
1
0 - 999
0
1
1 -
999
1 - 999
10
1 - 999
10
1-255
12
(1-255: 1-255h passed)
1 - 24
2
1 - 9
2
1-999
15
(Entry of 20 corresponds
to 100,000mm.)
1-999
15
(Entry of 20 corresponds
to 100,000mm.)
0 - 999
0
20
1 -
999
0 - 6
0
5
1 - 5
6
1 - 255
40
0 - 2
0
0
1
2
0 - 240 (MINUTE)
60
0 - 15 (HOUR)
1
0-15 (Above)+(HOUR)
5
1 - 999
200
1 - 999
300
1 - 999
500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-5000nMx-4101nMx-5001n

Table of Contents