Sharp MX-4100N Service Manual page 212

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

Item/Display
M
K_PAT TARGET ID
Patch density
standard value
(black)
N
HV BK_GROUND
Patch position
LIMIT
substrate light
receiving effective
range value
44-9
Purpose
Operation data display
Function (Purpose) Used to display the result data of the high
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
Select a target display mode with [CPY/PRN],[OTHER] keys.
Mode
Item/Display (*: Correction value)
CPY/PRN
P (PROCON)
N(M)
(NORMAL (MIDDLE))
N(L)
(NORMAL (LOW))
Setting
Default
Content
range
value
1 - 255
5
1 - 255
60
BLACK : GB ***/*** DV ***/***
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
BLACK : GB ***/*** DV ***/***
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
BLACK : GB ***/*** DV ***/***
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
MX-5001N SIMULATION 6 – 65
44-6
Purpose
Adjustment
Function (Purpose) Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed.
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
Result display
COMPLETE
Normal complete
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Content
High density process control GB/DV data
(KCMY)
(Actual output voltage level/base voltage
level)
High density normal (Medium speed
display) GB/DV data (KCMY)
(Actual output voltage level/base voltage
level)
High density normal (Low speed display)
GB/DV data (KCMY)
(Actual output voltage level/base voltage
level)
Content description
Content description
Default
Display range
value
GB: 230 - 850
GB: 630
DV: 0 - 700
DV: 430
GB: 230 - 850
GB: 630
DV: 0 - 700
DV: 430
GB: 230 - 850
GB: 600
DV: 0 - 700
DV: 400