[RSPF]
Item/
Content
Display
GAIN ODD
Gain adjustment value
(odd number)
GAIN EVEN
Gain adjustment value
(Even number)
OFFSET
Offset value
ODD
(odd number)
OFFSET
Offset value
EVEN
(even number)
SMP AVE
Reference plate
ODD
sampling average
value (ODD)
SMP AVE
Reference plate
EVEN
sampling average
value (EVEN)
TARGET
Target value
VALUE
BLACK
Black output level
LEVEL
ERROR
Error code
CODE
(0, 1-14)
(for debug)
RSPF
First scan
WHITE
RSPF white reference
LEVEL 1ST
level
RSPF
Second scan
WHITE
RSPF white reference
LEVEL 2ND
level
NOTE
0
No error
1
Loop number over
2
The target value is under
the specified value.
3
The gain set value is
negative.
4
END is not asserted.
(Gain adjustment)
5
(reserve)
6
Underflow
7
Black shading error
8
Other error
9
END is not asserted.
(White shading)
10
END is not asserted.
(Black shading)
11
END is not asserted.
(Light quantity correction)
12
END is not asserted.
(Scan)
13
Register check error.
(When booting/
Before gain)
14
Register check error.
(Before light quantity
correction)
MX-5001N SIMULATION 6 – 126
63-2
Purpose
Adjustment
Function (Purpose) Used to perform shading.
Section
Operation/Procedure
1)
(When DSPF model)
Select [OC SHADING] key or [DSPF SHADING] key, and
press [EXECUTE] key.
2)
(When RSPF model)
Press [EXECUTE] key.
Used to perform shading.
When the operation is completed, [EXECUTE] key returns to the
normal display.
63-3
Purpose
Adjustment
Function (Purpose) Used to perform scanner (CCD) color bal-
ance and gamma auto adjustment.
Section
Scanner
Operation/Procedure
1)
Place the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1)
on the reference position of the left rear frame side of the doc-
ument table.
2)
Select [OC] key or [DSPF] key. ([DSPF] key can be selected
only when the DSPF is installed.)
3)
Press [EXECUTE] key.
The scanner (CCD) color balance automatic adjustment is per-
formed.
When the operation is completed, [EXECUTE] key returns to the
normal display.
After completion of the operation, press [RESULT] key, and the
adjustment data are displayed. At that time, the target color of data
display can be selected with [R] [G] [B] key.