Sharp MX-4100N Service Manual page 62

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

Display/
Content
Item
MAIN
C
Registration
F
adjustment value
(Main scanning
direction) (Position
of writing by cyan
laser is F side)
M
Registration
adjustment value
(Main scanning
direction) (Position
of writing by
magenta laser is F
side)
Y
Registration
adjustment value
(Main scanning
direction) (Position
of writing by yellow
laser is F side)
MAIN
C
Registration
R
adjustment value
(Main scanning
direction) (Position
of writing by cyan
laser is R side)
M
Registration
adjustment value
(Main scanning
direction) (Position
of writing by
magenta laser is R
side)
Y
Registration
adjustment value
(Main scanning
direction) (Position
of writing by yellow
laser is R side)
SUB
C
Registration
adjustment value
(Sub scanning
direction) (Cyan
drum to black drum)
M
Registration
adjustment value
(Sub scanning
direction) (Magenta
drum to cyan drum)
Y
Registration
adjustment value
(Sub scanning
direction) (Yellow
drum to magenta
drum)
SKEW
C
Calculated result of
print skew amount
(Cyan)
M
Calculated result of
print skew amount
(magenta)
Y
Calculated result of
print skew amount
(yellow)
MAIN, SUB: The entered value after adjustment is displayed.
( ) is the difference from the previous adjustment value.
Example: This time 105, previous time 103: 105 (+2)
* In case of an error, "ERROR" is displayed with the details.
Dis-
De-
NOTE
play
fault
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
1.0 -
100
199.0
-99.9 -
If the value is plus,
99.9
-
R is displayed to
left side of
numerical value. If
-99.9 -
the value is minus,
99.9
-
L is displayed to left
side of numerical
-99.9 -
value. When the
99.9
value is in the -4 to
+4 range, "OK" is
displayed to right
-
side of numerical
value. If not, "NG"
is displayed to right
side of numerical
value.
MX-5001N ADJUSTMENTS 5 – 20
To check the auto adjustment result, use the manual image
registration adjustment mode below.
* Image registration adjustment (Main scanning direction) (Manual
adjustment) (SIM50-20)
* Image registration adjustment (Sub scanning direction) (Manual
adjustment) (SIM50-21)
10-B
Image registration adjustment (Main
scanning direction) (Manual adjustment)
NOTE: If item "AR_AUTO" in SIM44-1 is 0 (Allows) and process
control is executed, the image registration adjustment is
executed automatically and updates the result in each
case.
In case of retaining the manual adjustment result, 1 must be set to
item "AR_AUTO" of SIM44-1 (inhibits).
1)
Enter SIM50-20 mode.
10-key
EXECUTE
2)
Select the paper feed tray with A3 (11" x 17") paper in it by
changing the value of set item H.
3)
Press [EXECUTE] key.
The image registration adjustment pattern in the main scan-
ning direction is printed.
EXECUTE
End of print