43-20
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
[41-sheet machine]
1
Item/Display
A
HL_UM READY LL
B
HL_LM READY LL
C
HL_E READY LL
D
HL_UM PLAIN BW LL
E
HL_LM PLAIN BW LL
F
HL_E PLAIN BW LL
G
HL_UM PLAIN CL LL
H
HL_LM PLAIN CL LL
I
HL_E PLAIN CL LL
J
WARMUP FUMON HL_E T LL
K
WARMUP FUMOFF T LL
L
WARMUP END TIME LL
M
HL_UM HEAVY LL
N
HL_LM HEAVY LL
O
HL_E HEAVY LL
P
HL_UM OHP LL
Q
HL_LM OHP LL
R
HL_E OHP LL
S
HL_UM ENVELOPE LL
T
HL_LM ENVELOPE LL
U
HL_E ENVELOPE LL
V
HL_UM GLOSS LL
W
HL_LM GLOSS LL
X
HL_E GLOSS LL
Y
HL_UM E-STAR LL
Z
HL_E E-STAR LL
AA
PRE-JOB LL
Content
Correction value for TH_UM set value in Ready standby
under LL environment
Correction value for TH_LM set value in Ready standby
under LL environment
Correction value for TH_E set value in Ready standby
under LL environment
Correction value for Black-White plain paper TH_UM set
value under LL environment
Correction value for Black-White plain paper TH_LM set
value under LL environment
Correction value for Black-White plain paper TH_E set
value under LL environment
Correction value for Color plain paper TH_UM set value
under LL environment
Correction value for Color plain paper TH_LM set value
under LL environment
Correction value for Color plain paper TH_E set value
under LL environment
Correction value for fusing motor pre-rotation start TH_E
set value under LL environment
Fusing motor prior rotation completion time under LL
environment
Correction value for warm-up complete time under LL
environment
Correction value for heavy paper TH_UM set value under
LL environment
Correction value for heavy paper TH_LM set value under
LL environment
Correction value for heavy paper TH_E set value under LL
environment
Correction value for OHP TH_UM set value under LL
environment
Correction value for OHP TH_LM set value under LL
environment
Correction value for OHP TH_E set value under LL
environment
Correction value for envelope TH_UM set value under LL
environment
Correction value for envelope TH_LM set value under LL
environment
Correction value for envelope TH_E set value under LL
environment
Correction value for glossy paper TH_UM set value under
LL environment
Correction value for glossy paper TH_LM set value under
LL environment
Correction value for glossy paper TH_E set value under LL
environment
Correction value for preheating TH_UM set value under LL
environment
Correction value for preheating TH_E set value under LL
environment
Correction value for resetting from preheating
TH_UM+TH_E set value under LL environment
MX-5001N SIMULATION 6 – 51
Correction value: -49 - +49, 1 Count = 1°C Change
Correction
-49
-25
-5
value
Input value
1
25
45
Setting
range
Group 1
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
45
1 - 99
50
1 - 99
80
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
50
1 - 99
55
1 - 99
55
1 - 99
55
0
5
25
49
50
55
75
99
Default value
Destination
linkage
Group 2
Group 3
(NOTE)
55
55
55
55
55
55
55
55
55
55
50
50
55
55
55
55
50
50
45
45
50
50
80
80
55
55
55
55
50
50
55
55
55
55
50
50
55
55
55
55
50
50
55
55
55
55
50
50
55
55
55
55
55
55