44-16
Purpose
Operation data display
Function (Purpose) Used to display the toner density control
data.
Section
Developing system
Operation/Procedure
1)
Select a target color with [K] [C] [M] [Y] key.
The toner density control data are displayed.
Item/
Content
Display
TONER
The current toner density sensor
DEN_LT (M)
output value (final value) at the
medium speed
TONER
The current toner density reference
DEN_ST (M)
value display (including all the
correction values) at the medium
speed
TONER
The current toner density sensor
DEN_LT (L)
output value (final value) at the low
speed
TONER
The current toner density reference
DEN_ST (L)
value display (including all the
correction values) at the low speed
Item/Display
Content
AUTO DEVE
Auto
Sensor output value
(M)
development
after completion of
adjustment
SIM25-02
value
(at the medium
(At the
speed)
medium
speed)
ALL (M)
All the
Correction reference
correction
value which
reference
calculated all the
values
correction values for
(At the
the auto
medium
development
speed)
adjustment value
(at the medium
speed)
AUTO DEVE
Auto
Sensor output value
(L)
development
after completion of
adjustment
SIM25-02
value
(at the low speed)
(At the low
speed)
ALL (L)
All the
Correction reference
correction
value which
reference
calculated all the
values
correction values for
(At the low
the auto
speed)
development
adjustment value
(at the low speed)
Item/Display
AREA
HUD
PRINT RATE
PROCON
LIFE
SENSITIVITY
AUTO DEVE
VO (M)
Setting
Default
range
value
ALL VO (M)
1 - 255
129
128
129
AUTO DEVE
VO (L)
128
Setting
Default
ALL VO (L)
range
value
1 - 255
128
AREA VO
HUD VO
PRINT RATE
VO
PROCON VO
LIFE VO
SENSITIVITY
VO
MX-5001N SIMULATION 6 – 68
Content
Area
Correction value for
correction
the environment
value
area
Humidity
Correction value for
correction
change in humidity
value
Print ratio
Correction value for
correction
document print ratio
value
Process
Correction value for
control
high density process
correction
control result
value
Life
Correction value for
correction
the developer life
value
Sensitivity
Correction for the
correction
toner density
value
sensitivity
Auto
Sensor control
development
voltage value after
adjustment
completion of
control
SIM25-02
voltage
(at the medium
(at the
speed)
medium
speed)
All the
Control voltage
correction
reference value
reference
which calculated all
control
the correction values
voltages
for the auto
(at the
development
medium
adjustment value
speed)
(at the medium
speed)
Auto
Sensor control
development
voltage value after
adjustment
completion of
control
SIM25-02
voltage
(at the low speed)
(at the low
speed)
All the
Control voltage
correction
reference value
reference
which calculated all
control
the correction values
voltages
for the auto
(at the low
development
speed)
adjustment value
(at the low speed)
Area
Control voltage
correction
correction value for
control
the environment
voltage
area
Humidity
Control voltage
correction
correction value for
control
change in humidity
voltage
Print ratio
Control voltage
correction
correction value for
control
the document print
voltage
ratio
Process
Control voltage
control
correction value for
correction
the high density
control
process control
voltage
result
Life
Control voltage
correction
correction value for
value control
the developer life
voltage
Sensitivity
Control voltage
correction
correction value for
control
the toner density
voltage
sensor
Setting
Default
range
value
-127 -
0
127
1 - 999
500
1 - 255
128
-127 -
0
127
1 - 999
500

Advertisement