When the above operation is nor performed normally, "ERROR" is
displayed and. When the above operation is completed normally,
"COMPLETE" is displayed.
1
TRAYVOLMAX
Tray size volume maximum value
2
TRAYVOLA4R
Tray volume A4R size adjustment value
3
TRAYVOLA5R
Tray volume A5R size adjustment value
4
TRAYVOLMIN
Tray size volume minimum value
53-7
Purpose
Adjustment/Setup
Function (Purpose) Used to adjust the RSPF/DSPF document
size width sensor.
Section
Operation/Procedure
1)
Select an adjustment target item with [↑] [↓] key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
[RSPF]
Item/Display
A
AD_MAX
Max. width position
B
AD_P1
A4R width position
C
AD_P2
A5R width position
D
AD_MIN
Min. width position
[DSPF]
Item/Display
A
AD_MAX
Max. width position
B
AD_P1
A4R width position
C
AD_P2
A5R width position
D
AD_MIN
Min. width position
53-8
Purpose
Function (Purpose) Used to adjust the document lead edge ref-
Section
Operation/Procedure
Select an adjustment item with [AUTO] [MANUAL] key.
<AUTO: Document lead edge reference (RRCA) adjustment>(Auto
adjustment)
1)
2)
Item/Display
MEASUREMENT
DISTANCE
RRCA
<MANUAL: RSPF/DSPF mode document scan position adjust-
ment>
1)
2)
Item/Display
A
• When the adjustment value is increased, the scanner stop posi-
tion in the RSPF/DSPF mode is shifted to the right.
• When the adjustment value is changed by 1, the position is
Setting
Default
shifted by 0.1mm.
range
value
0 - 1023
72
0 - 1023
499
0 - 1023
805
0 - 1023
955
Setting
Default
range
value
0 - 1023
66
0 - 1023
438
0 - 1023
699
0 - 1023
893
MX-5001N SIMULATION 6 – 117
Adjustment
erence and the RSPF/DSPF mode docu-
ment scan position.
Set a sheet of black paper of A4 or 11"x 8.5" on the document
table.
Press [EXCUTE] key. (The adjustment is performed and the
adjustment value is saved.)
Content
Document lead edge
measurement distance
Document lead edge
reference position
Enter the set value with 10-key.
Press [OK] key. (The set value is saved.)
Content
ADJUST
RSPF/DSPF mode document
VALUE
scan position adjustment
(Scanner stop position
adjustment)
Setting
Default
range
value
0-255
-
(0.1mm unit)
0 - 99
50
Setting
Default
range
value
1 - 99
10