<Code descriptions>
TH_UM
Fusing upper thermister main center
TH_LM
Fusing lower thermister main
TH_E
Fusing thermister external
43-31
Purpose
Adjustment/Setup
Function (Purpose) Used to check the operation of the fusing
web cleaning motor.
Section
Fusing
Operation/Procedure
1)
Press [EXECUTE] key.
Perform the fusing web cleaning motor drive.
2)
When driving the fusing web cleaning motor is completed,
"COMPLETE" is displayed.
Fusing web unit
Operation
installation detection
state
Fusing web unit
Not operate
installed
Fusing web unit not
10sec continuous
installed
rotation
* The fusing web unit is used by installing to the fusing unit. For
checking the fusing web cleaning motor rotation, remove the
whole fusing unit and check with the door open.
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_E
Heater lamp external
Remark
* During this operation,
the fusing web cleaning
feed counter is not
counted up.
MX-5001N SIMULATION 6 – 62
43-32
Purpose
Adjustment/Setup
Function (Purpose) Used to set various items related to the
forcible operation of web cleaning when job
end.
Section
Fusing
Operation/Procedure
1)
Select an item to be set with [↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
Item
Display
A
JOB END
Fusing web
COMP ACT
motor forcible
CHECK
operation
condition when
job end
B
JOB END
The fusing web motor is
COMP ACT
forcibly operated when job
INTERVAL
end.
Print quantity interval
C
JOB END
Number of forcible
COMP ACT
operations of the fusing
CNT
web motor when job end
Setting
Default
Item
range
value
Enable
0 - 1
0
1
Disable
1
1 - 200
100
1 - 5
1