Sharp MX-4100N Service Manual page 367

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

D. Emergency update (incase of an HDD
breakdown)
The HDD of this machine stores the main program along with the
sophisticated variations.
When, therefore, the HDD breaks down, or when the HDD must be
replaced with another HDD, or when the main program is damaged
by turning OFF the power during the firmware updating, the firm-
ware (main program) must be rewritten into the HDD by the follow-
ing procedures. It is called the emergency update.
[Conditions where the emergency update is required]
The emergency update is required in the following cases:
1)
"Main Program Error" is displayed on the panel.
It means that the data are destroyed and that replacement of
the HDD is not required. The problem can be settled by execu-
tion of the emergency update only.
2)
"HDD Trouble (E7-03)" is displayed on the panel.
It means a HDD breakdown. The HDD must be replaced with a
new one, and the emergency update must be executed.
* When U2-05 (HDD/EEPROM/SRAM abnormality) or U2-50
(HDD data abnormality related to IMS) occurs, execute SIM16
only, and there is no need to execute the emergency update.
[Environment necessary for the emergency update]
1)
The MFP with the HDD where the firmware is rewritten
2)
The USB memory which stores the firmware for the emer-
gency upgrade.
File name: emupdate_J2.sfu
* The firmware must be stored in the root folder of the USB
memory.
[Emergency update procedures]
1)
Insert the USB memory which stores the firmware for the
emergency update into the USB port.
2)
Turn on the main power.
The firmware for the emergency update in the USB memory is
automatically recognized to start reading the USB memory.
It takes about 1 minute, and the booting animation is displayed
during this period.
3)
Check to confirm that "EmergencyUpdateMode" is displayed
on the panel.
After that, the process is automatically executed.
EmergencyUpdateMode
4)
Check the procedure.
When the process is going on normally, the following message
is displayed.
EmergencyUpdateMode
Updating ....10%
5)
Check the update result.
When writing the program both to the HDD and to the Flash
ROM is normally completed, the following message is dis-
played.
If writing to either of the HDD or the Flash ROM is failed, the
following message is displayed.
In this case, if "Update Failed" is displayed, it may the HDD
has been broken down probably. Replace the HDD with a new
one, and execute the emergency update again.
6)
Turn OFF the main power.
7)
Remove the USB memory from the USB port.
8)
Turn ON the main power.
9)
Check the system operates normally.
10) When the HDD is replaced, use SIM49-5 to upload the water-
mark data.
11) Select the folder for updating, and press [EXECUTE] and
[YES] keys in this order to start the updating procedures.
[Note]
• It takes about 6 minutes for the emergency update.
• Never turn OFF the main power until the emergency update is
completed.
• When the emergency update is completed, be sure to remove
the USB memory for the emergency update. The machine does
not boot normally with the USB memory inserted.
MX-5001N FIRMWARE UPDATE 9 – 4
EmergencyUpdateMode
Update Succeeded
EmergencyUpdateMode
Update Failed