6-6
Purpose
Operation test/check
Function (Purpose) Used to check the operation of the fusing
separation.
Section
Fusing
Operation/Procedure
1)
Press [FUSER] key to highlight it.
2)
Press [EXCUTE] key, and fusing pressure applying and fusing
pressure release are repeated.
During this period, the status of the fusing roller pressure is dis-
played.
PRINT
Fusing pressure
applying
FREE
Fusing pressure
release
7
7-1
Purpose
Setting
Function (Purpose) Used to set the operating conditions of
aging.
Section
Others
Operation/Procedure
1)
Select the target to be set with the touch panel key.
2)
Press [EXECUTE] key.
The machine is rebooted in the aging mode.
The aging operation condition set by this mode is maintained here-
after unless the power is turned off or the setting is changed.
AGING
Aging operation setup
INTERVAL
Intermittent setup
MISFEED DISABLE
JAM detection enable/disable setup
FUSING DISABLE
Fusing operation enable/disable setup
WARMUP DISABLE
Warm-up skip setup
DV CHECK DISABLE
DV unit detection enable/disable setup
SHADING DISABLE
Shading disable setup
CCD GAIN FREE
No setting of the CCD gain adjustment
Fusing pressure applying → Fusing
pressure release → (Fusing pressure
applying) The operation is repeated.
MX-5001N SIMULATION 6 – 16
7-6
Purpose
Setting
Function (Purpose) Used to set the operating intermittent aging
cycle.
Section
Operation/Procedure
1)
Enter the intermittent aging operation cycle (unit: sec) with 10-
key.
2)
Press [OK] key.
The time entered in procedure 1) is set.
* The interval time that can be set is 1 to 900 (sec).
The aging operation condition set by this mode is maintained here-
after unless the power is turned off or the setting is changed.
7-8
Purpose
Operation display
Function (Purpose) Used to display the warm-up time.
Section
Operation/Procedure
Press [EXECUTE] key.
Counting of the warm-up time is started and the time required for
warm-up is displayed
* Interruption of counting by pressing [EXECUTE] key is inhibited.