Sharp MX-4100N Service Manual page 188

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

27-6
Purpose
Setting
Function (Purpose) Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
0
Allow (Default)
1
Inhibit
2)
Press [OK] key.
The set value in step 1) is saved.
27-7
Purpose
Setting
Function (Purpose) Used to set of the enable, alert callout.
(FSS function)
Section
Operation/Procedure
1)
Select an item to be set with [↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
A
FSS
0
FUNCTION
1
B
ALERT
0
1
*1 The FSS function setting can be changed only from Disable to
Enable. (Cannot be changed from Enable to Disable.)
*2 Alert send timing
No alert cause
Initial state / Trouble / Continuous JAM alert
Maintenance
When the maintenance timing is reached.
Service call
When pressing Service call.
Toner send request
When the toner order automatic send setting is
reached.
Toner collection request
Revision of the toner installation date (only for
a new product)
Alert resend
FSS function enable
FSS function disable (*1) (Default)
Alert call enable (*2) (Default)
Alert call disable
MX-5001N SIMULATION 6 – 41
27-9
Purpose
Setting
Function (Purpose) Used to set the paper transport time record-
ing YES/NO threshold value and shading
gain adjustment retry number.
(FSS function)
Section
Operation/Procedure
1)
Select an item to be set with [↑] [↓] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
A
FEED TIME 1
B
FEED TIME 2
C
GAIN
0 - 20
ADJUSTMENT
RETRY
D
JAM ALERT
* Items A, B: 0%, standard passing time between sheets of paper;
100%, time for judgment as a jam between sheets of paper.
* Item C: Because of a trouble in shading operation, the number of
retry is actually not registered.
0 -
Threshold value of the paper
100
transport time between sensors
(Main unit) (50: Default)
0 -
Threshold value of the paper
100
transport time between sensors
(RSPF) (50: Default)
Threshold value of the gain
adjustment retry number
(11: Default)
1 -
Alert judgment threshold value
100
for occurrence of continuous
jams
Alert judgment threshold value
for occurrence of continuous
jams (Setting of the number of
times of continuous jams as the
alert for continuous jams)
(Default: 10 times)