Sharp MX-4100N Service Manual page 214

Digital full color multifunctional system
Hide thumbs Also See for MX-4100N:
Table of Contents

Advertisement

44-12
Purpose
Operation data display
Function (Purpose) Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
Select a display mode with [TARGET] [PATCH] keys.
Mode
Item/Display
TARGET
CARB DATA
Calibration plate
(1 page)
detection level
SEAL ADJ
Jig patch seal
DATA
detection level when
executing SIM 44-13
ADK_SL (K)
Development
characteristics
gradient coefficient
(High density process
control operation)
ADK_INT(K)
Development
characteristics
intercept level (High
density process
control operation 0V)
TARGET (K)
High density process
control target density
level (K)
TARGET
High density process
(C/M/Y)
control target density
level (C/M/Y)
PATCH
n-1
High density process
1-5
control nth time patch
(Page 1-2)
density level 1 (n=1-
5)
n-2
Patch data nth time
patch 2 (n=1-5)
n-3
Patch data nth time
patch 3 (n=1-5)
n-4
Patch data nth time
patch 4 (n=1-5)
• BK only
n-5
Patch data nth time
patch 5 (n=1-5)
• BK only
PATCH
n-1
Patch data nth time
6-10
patch 1 (n=6-10)
(Page 1-2)
n-2
Patch data nth time
patch 2 (n=6-10)
n-3
Patch data nth time
patch 3 (n=6-10)
n-4
Patch data nth time
patch 4 (n=6-10)
• BK only
n-5
Patch data nth time
patch 5 (n=6-10)
• BK only
Display
Default
Content
range
value
0 - 255
108
1 - 255
108
-9.99 -
0
9.99
-999.9 -
0
999.9
0.00 -
0
255.00
0.00 -
0
255.00
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
0 - 255
0
MX-5001N SIMULATION 6 – 67
44-13
Purpose
Adjustment/Setup
Function (Purpose) Used to perform the color image sensor
(image registration sensor F) calibration.
Section
Operation/Procedure
1)
Attach the calibration jig.
2)
Press [EXECUTE] key.
Calibration is performed, and the data are displayed.
Item/Display
A
PCS_CL CARB OUT
Calibration plate
sensor value
B
PCS_CL LED ADJ
Color sensor light
emitting quantity
adjustment value
44-14
Purpose
Operation data display
Function (Purpose) Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
Item/Display
Content
TH_UM
Fusing upper thermister main
detection temperature (°C)
Difference AD input value (AD
value)
TH_UM_AD1
Fusing upper thermister main
compensation temperature (°C)
AD value (AD value)
TH_UM_AD2
Fusing upper thermister main
detection sensor AD value (AD
value)
TH_LM
Fusing lower thermister main A/D
value (temperature °C)
TH_E
Fusing external thermistor A/D
value (temperature °C)
TEMPRATURE
Temperature thermister
HUMIDITY
Humidity sensor
TH1_LSU
LSU thermister 1 A/D value
(temperature °C)
Setting
Default
Content
range
value
1 - 255
108
1 - 255
21
Display range
Temperature:
0 - 255°C(±1°C)
AD value: 0-1023
Temperature:
0.0-255.0°C
(±0.2°C)
AD value: 0-1023
AD value:0-1023
Temperature:
0 - 255°C(±1°C)
AD value: 0-1023
Temperature:
0 - 255°C(±1°C)
AD value: 0-1023
Temperature:
-40.0 - 60.0°C
(±0.1°C)
AD value: 0-1023
Humidity:
5.0-90.0% (±0.1%),
AD value: 0-1023
Temperature:
5.0-60.0°C
(±0.1°C)
AD value: 0-255