Function Test Of Safety Switches - ABB OmniCore V250XT Type B Product Manual

Table of Contents

Advertisement

4 Maintenance

4.5.4 Function test of safety switches

4.5.4 Function test of safety switches
Performing the motor function test
1
2
3
Performing the brake function test
1
2
3
176
Action
Start the robot system and change the op-
erating mode to manual.
Press the three-position enabling device
to the middle position and then hold the
enabling device in this position.
Release the three-position enabling device.
Action
Start the robot system and change the op-
erating mode to manual.
Press the three-position enabling device
to the middle position and then hold the
enabling device in this position.
While having eye contact with the manipu-
lator, move the joystick slightly in any dir-
ection to disengage the brakes.
Release the three-position enabling device
to engage the brakes.
© Copyright 2023-2023 ABB. All rights reserved.
Note
This test is passed if the event message
10011 Motors ON state appears in the
event log.
If the event message 37001 Motor on activ-
ation error appears in the event log, then
the test has failed and the root cause of the
failure must be found.
This test is passed if the event message
10012 Safety guard stop state appears in
the event log.
If the event message 90227 Motor contact-
or conflict appears in the event log, then
the test has failed and the root cause of the
failure must be found.
Note
This test is passed if the brakes are disen-
gaged and the manipulator can be moved.
If the event message 50056 Joint collision
appears in the event log, then the test has
failed and the root cause of the failure must
be found.
This test is passed if the event message
10012 Safety guard stop state appears in
the event log.
If the event message 37101 Brake Failure
appears in the event log, then the test has
failed and the root cause of the failure must
be found.
Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A

Advertisement

Table of Contents
loading

Table of Contents