Dimensions
Parameter
Width
Depth
Height
Weight
Controller
OmniCore V250XT Type B
Transportation and storage conditions
Parameter
Minimum ambient temperature
Maximum ambient temperature
Maximum ambient temperature (less than 24
hrs)
Shock and Vibration
After storage, the operating conditions inside the controller must be met for at least
6 hours before switching on the controller (see
The robot controller shall be stored according to its IP classification (IP54), that is,
indoors, in an environment that is dry and dust-free. In addition, wind, temperature
fluctuations, and condensation shall be avoided.
See also Product specification - OmniCore V line.
Operating conditions
The table shows the allowed operating conditions for the controller.
Parameter
Minimum ambient temperature
Maximum ambient temperature
Maximum ambient altitude
Shock and Vibration
Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
2.2 Technical data for OmniCore V250XT Type B controller
Note
The weight does not include any mounting kits fitted on the controller.
© Copyright 2023-2023 ABB. All rights reserved.
2 Controller description
Value
650 mm
480 mm
960 mm
Weight
85 kg
Value
-40°C (-40°F)
+55°C (+131°F)
+70°C (+158°F)
In accordance with ETSI EN 300 019-2-2 /
Environmental class 2.3
(No severity reduction for horizontal axes)
2
Max. 5 g = 50 m/s
(11 ms)
Operating conditions on page
Value
+5°C (+41°F)
+45°C (+113°F)
2,000 m
In accordance with ETSI EN 300 019-2-3 /
Environmental class 3.5 (3M5)
(Random vibration)
Continues on next page
Continued
39).