Refitting the safety digital base device
Refitting the safety digital base device
1
2
3
4
Concluding procedure
1
Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Push the digital base into the bracket
until you hear a clear clicking sound.
Reconnect any connectors disconnected
at removal.
Action
Close the door.
© Copyright 2023-2023 ABB. All rights reserved.
5.2.7 Replacing the safety digital base device
Note/Illustration
Location of wrist strap button:
xx2200001817
xx2200001972
Note/Illustration
Closing the door on page
Continues on next page
5 Repair
Continued
185.