5 Repair
5.2.4 Replacing the 3G Connected Services gateway
Continued
Disconnecting the antenna
1
2
3
4
5
Removing the Connected Services gateway
1
Continues on next page
212
Action
Record the cable routing when you re-
move the antenna cable from the cabinet.
Disconnect the antenna cable from the
Connected Services gateway by rotating
the connector.
Remove any cable ties and protection.
Pull the cable out through the cable
grommet.
Remove the magnet part of the antenna
from the cabinet.
Action
Disconnect all connectors from the unit
to be replaced.
© Copyright 2023-2023 ABB. All rights reserved.
Note/Illustration
Note
The Connected Services antenna is installed
by the customer, and the cable routing can
therefore differ.