Refitting the manipulator signal connector
Refitting the manipulator signal connector
1
2
3
4
5
Concluding procedure
1
2
Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
5.3.1 Replacing the manipulator signal connector (SMB)
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Insert the manipulator signal connector
into the cover plate in the front panel.
Secure it with the attachment screws.
Reconnect any connectors disconnected
at removal.
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
173.
© Copyright 2023-2023 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
Tightening torque: 2.7 Nm±10%.
xx2200001981