3 Installation and commissioning
3.7.5 Installing the power supply optional device
Continued
Required spare parts
Spare part
DSQC 609 power supply
DSQC 634 power supply
Harness PSU 24V
Harness PSU
End clamp
Required tools and equipment
Equipment
Standard toolkit
ESD protective wrist band
Required documents
Document
Circuit diagram - OmniCore
V250XT, rev 04 or later
Installing the optional power supply
Preparations
1
2
Continues on next page
132
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore V250XT Type B via myABB Business Portal,
www.abb.com/myABB.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
Open the door.
© Copyright 2023-2023 ABB. All rights reserved.
Article number
Note
3HAC14178-1
DSQC 609
3HAC13398-2
DSQC 634
3HAC082083-001
DSQC 609 and DSQC 634
3HAC082508-001
DSQC 609 and DSQC 634
3HAB7983-1
Article number
Note
-
Content is defined in section
Standard toolkit for controller on
page
-
Article number
Note
3HAC074000-008
Note/Illustration
Opening the door on page
Product manual - OmniCore V250XT Type B
426.
184.
3HAC087112-001 Revision: A