Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
Reconnect any connectors disconnected
at removal.
Secure the motor connector cables with
the velcro on the frame of the cabinet.
Tip
Use the same position as from removing
the motor connector.
© Copyright 2023-2023 ABB. All rights reserved.
5.3.2.1 Replacing the motor connector
Note/Illustration
Location of wrist strap button:
xx2200001817
Screws: Torx, countersunk screw M4x10 (4
pcs)
Tightening torque: 2.7 Nm±10%.