Removing the drive unit
1
2
3
Refitting the additional drive unit
Refitting the additional drive unit
1
Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
Action
Pull the cable ties out from the locking
holes.
Tip
Take photos of the cable ties and locking
holes before pulling out, to have as a
reference when refitting the cable ties.
Disconnect all connectors from the unit
to be replaced.
Remove the screws and pull the drive
unit out from the two guiding pins on the
mounting plate.
CAUTION
The cabling is sensitive to mechanical
damage. Handle it with care to avoid
damage to the cabling or the connector,
avoid any kind of tilt or skew.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
© Copyright 2023-2023 ABB. All rights reserved.
5.2.14 Replacing the additional drive unit
Note/Illustration
Lengthened screwdriver
xx2200001375
Note/Illustration
Continues on next page
5 Repair
Continued
269