Table 30-1
Example: Limit Line Formatting (*.csv) (Sheet 1 of 2)
Description of Limit Line
#Comments start with "#"
Description
Enabled
Fixed/Relative
Lower/Upper
LimitLines
a
Frequency
5000000000
10000000000
20000000000
30000000000
#Comment 2 (Example)
#Comment 3 (Example)
Enabled
Fixed/Relative
Lower/Upper
LimitLines
a
Frequency
5000000000
10000000000
20000000000
756
Data Analysis FeaturesDELETE_IF
All about Limit Lines
LimitExample
TRUE
Fixed
Upper
b
Amplitude
–70
–70.5
–80
–80
TRUE
Fixed
Upper
b
Amplitude
–50
–50
–50.5
Notes
Any row that begins with # is
ignored by the FieldFox.
Example "LimitExample" name
only. Use any descriptive name.
Choose: TRUE or FALSE
Choose: Fixed or Relative
Choose: Lower or Upper
Must literally read: "LimitLines".
This indicates the limit line's
definitions begins below.
These must be written literally as
"Frequency" and "Amplitude".
Any row that begins with # is
ignored by the FieldFox.
Any row that begins with # is
ignored by the FieldFox.