ABB RELION 670 Series Technical Manual page 790

Generator protection
Hide thumbs Also See for RELION 670 Series:
Table of Contents

Advertisement

Section 14
Control
Name
1189G_OP
1189G_CL
2189G_OP
2189G_CL
7189G_OP
7189G_CL
BBTR_OP
BC_12_CL
VP_BBTR
VP_BC_12
EXDU_89G
EXDU_12
EXDU_BC
152O_EX1
152O_EX2
152O_EX3
189_EX1
189_EX2
189_EX3
289_EX1
289_EX2
289_EX3
2089_EX1
2089_EX2
789_EX1
789_EX2
Table 457: ABC_BC (3) Output signals
Name
152OPREL
152OPITL
152CLREL
152CLITL
189REL
189ITL
289REL
289ITL
Table continues on next page
784
Type
Default
Description
BOOLEAN
0
Grounding switch 1189G on busbar 1 is in open position
BOOLEAN
0
Grounding switch 1189G on busbar 1 is in closed position
BOOLEAN
0
Grounding switch 2189G on busbar 2 is in open position
BOOLEAN
0
Grounding switch 2189G on busbar 2 is in closed position
BOOLEAN
0
Grounding switch 7189G on busbar 7 is in open position
BOOLEAN
0
Grounding switch 7189G on busbar 7 is in closed position
BOOLEAN
0
No busbar transfer is in progress
BOOLEAN
0
A bus coupler connection exists between busbar Bus1 and Bus2
BOOLEAN
0
Status are valid for apparatuses involved in the busbar transfer
BOOLEAN
0
Status of the bus coupler apparatuses between Bus1 and Bus2 are
valid
BOOLEAN
0
No transm error from any bay containing grounding switches
BOOLEAN
0
No transm error from any bay connected to WA1/WA2 busbars
BOOLEAN
0
No transmission error from any other bus coupler bay
BOOLEAN
0
External open condition for apparatus 152
BOOLEAN
0
External open condition for apparatus 152
BOOLEAN
0
External open condition for apparatus 152
BOOLEAN
0
External condition for apparatus 189
BOOLEAN
0
External condition for apparatus 189
BOOLEAN
0
External condition for apparatus 189
BOOLEAN
0
External condition for apparatus 289
BOOLEAN
0
External condition for apparatus 289
BOOLEAN
0
External condition for apparatus 289
BOOLEAN
0
External condition for apparatus 2089
BOOLEAN
0
External condition for apparatus 2089
BOOLEAN
0
External condition for apparatus 789
BOOLEAN
0
External condition for apparatus 789
Type
Description
BOOLEAN
Opening of 152 is allowed
BOOLEAN
Opening of 152 is not allowed
BOOLEAN
Closing of 152 is allowed
BOOLEAN
Closing of 152 is not allowed
BOOLEAN
Switching of 189 is allowed
BOOLEAN
Switching of 189 is not allowed
BOOLEAN
Switching of 289 is allowed
BOOLEAN
Switching of 289 is not allowed
1MRK 502 066-UUS B
PID-3500-OUTPUTSIGNALS v5
Technical manual