ABB RELION 670 Series Technical Manual page 463

Generator protection
Hide thumbs Also See for RELION 670 Series:
Table of Contents

Advertisement

1MRK 502 066-UUS B
Name
Values (Range)
tTRCrv1
0.005 - 100.000
tCRCrv1
0.1 - 10.0
HarmBlock1
Disabled
Enabled
ResetTypeCrv2
Instantaneous
IEC Reset
ANSI reset
tReset2
0.000 - 60.000
tPCrv2
0.005 - 3.000
tACrv2
0.005 - 200.000
tBCrv2
0.00 - 20.00
tCCrv2
0.1 - 10.0
tPRCrv2
0.005 - 3.000
tTRCrv2
0.005 - 100.000
tCRCrv2
0.1 - 10.0
HarmBlock2
Disabled
Enabled
ResetTypeCrv3
Instantaneous
IEC Reset
ANSI reset
tReset3
0.000 - 60.000
tPCrv3
0.005 - 3.000
tACrv3
0.005 - 200.000
tBCrv3
0.00 - 20.00
tCCrv3
0.1 - 10.0
tPRCrv3
0.005 - 3.000
tTRCrv3
0.005 - 100.000
tCRCrv3
0.1 - 10.0
HarmBlock3
Disabled
Enabled
ResetTypeCrv4
Instantaneous
IEC Reset
ANSI reset
Table continues on next page
Technical manual
Unit
Step
Default
-
0.001
13.500
-
0.1
1.0
-
-
Disabled
-
-
Instantaneous
s
0.001
0.020
-
0.001
1.000
-
0.001
13.500
-
0.01
0.00
-
0.1
1.0
-
0.001
0.500
-
0.001
13.500
-
0.1
1.0
-
-
Disabled
-
-
Instantaneous
s
0.001
0.020
-
0.001
1.000
-
0.001
13.500
-
0.01
0.00
-
0.1
1.0
-
0.001
0.500
-
0.001
13.500
-
0.1
1.0
-
-
Disabled
-
-
Instantaneous
Description
Parameter TR for customer programmable
curve for step 1
Parameter CR for customer programmable
curve for step 1
Enable block of step 1 for harmonic
restraint
Selection of reset curve type for step 2
Constant reset time for step 2
Parameter P for customer programmable
curve for step 2
Parameter A for customer programmable
curve for step 2
Parameter B for customer programmable
curve for step 2
Parameter C for customer programmable
curve for step 2
Parameter PR for customer programmable
curve for step 2
Parameter TR for customer programmable
curve for step 2
Parameter CR for customer programmable
curve for step 2
Enable block of step 2 for harmonic
restraint
Selection of reset curve type for step 3
Constant reset time for step 3
Parameter P for customer programmable
curve for step 3
Parameter A for customer programmable
curve for step 3
Parameter B for customer programmable
curve for step 3
Parameter C for customer programmable
curve for step 3
Parameter PR for customer programmable
curve for step 3
Parameter TR for customer programmable
curve for step 3
Parameter CR for customer programmable
curve for step 3
Enable block of step 3 for harmonic
restraint
Selection of reset curve type for step 4
Section 8
Current protection
457