ABB RELION 670 Series Technical Manual page 1182

Generator protection
Hide thumbs Also See for RELION 670 Series:
Table of Contents

Advertisement

Section 18
Station communication
18.8.11.3
Function block
BLOCK
IEC10000283 V1 EN-US
Figure 603: I103IEDCMD function block
18.8.11.4
Signals
Table 879: I103IEDCMD Input signals
Name
BLOCK
Table 880: I103IEDCMD Output signals
Name
19-LEDRS
23-GRP1
24-GRP2
25-GRP3
26-GRP4
18.8.11.5
Settings
Table 881: I103IEDCMD Non group settings (basic)
Name
Values (Range)
FunctionType
1 - 255
18.8.12
Function commands user defined for IEC 60870-5-103
I103USRCMD
18.8.12.1
Functionality
I103USRCMD is a command block in control direction with user defined output signals. These
function blocks include the
Information number parameter for each output signal.
1176
I103IEDCMD
19-LEDRS
23-GRP1
24-GRP2
25-GRP3
26-GRP4
IEC10000283-1-en.vsd
Type
Default
BOOLEAN
0
Type
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
Unit
-
FunctionType parameter for each block in the private range, and the
Description
Block of commands
Description
Information number 19, reset LEDs
Information number 23, activate setting group 1
Information number 24, activate setting group 2
Information number 25, activate setting group 3
Information number 26, activate setting group 4
Step
Default
1
255
1MRK 502 066-UUS B
GUID-52D27CDA-8805-48FA-99BE-2E05A438B0C7 v1
Description
Function type (1-255)
GUID-2989EAC8-20BE-46EE-93FE-C70188D0BC89 v1
Technical manual
PID-3788-INPUTSIGNALS v4
PID-3788-OUTPUTSIGNALS v4
PID-3788-SETTINGS v4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reg670

Table of Contents