ABB RELION 670 Series Technical Manual page 1164

Generator protection
Hide thumbs Also See for RELION 670 Series:
Table of Contents

Advertisement

Section 18
Station communication
Function block
SINGLECMD3-Cmd1
SINGLECMD3-Cmd2
SINGLECMD3-Cmd3
SINGLECMD3-Cmd4
SINGLECMD3-Cmd5
SINGLECMD3-Cmd6
SINGLECMD3-Cmd7
SINGLECMD3-Cmd8
SINGLECMD3-Cmd9
SINGLECMD3-Cmd10
SINGLECMD3-Cmd11
SINGLECMD3-Cmd12
SINGLECMD3-Cmd13
SINGLECMD3-Cmd14
SINGLECMD3-Cmd15
SINGLECMD3-Cmd16
Figure
592
command function via the configuration logic circuit in a protection IED for control of a circuit
breaker.
A pulse via the binary outputs of the IED normally performs this type of command control. The SPA
addresses to control the outputs OUT1 – OUT16 in SINGLECMD:1 are shown in table 857.
#CD01-CMDOUT1
#CD01-CMDOUT2
#CD01-CMDOUT3
#CD01-CMDOUT4
#CD01-CMDOUT5
#CD01-CMDOUT6
#CD01-CMDOUT7
#CD01-CMDOUT8
#CD01-CMDOUT9
#CD01-CMDOUT10
#CD01-CMDOUT11
#CD01-CMDOUT12
#CD01-CMDOUT13
#CD01-CMDOUT14
#CD01-CMDOUT15
#CD01-CMDOUT16
IEC05000717 V3 EN-US
Figure 592: Application example showing a simplified logic diagram for control of a circuit
The MODE input defines if the output signals from SINGLECMD:1 is off, steady or setable pulse
length signals. This is set in Parameter Setting Tool (PST) under: Main Menu/Settings / IED
Settings / Control / Commands / Single Command or via Parameter Setting Tool (PST).
Event function
Event function is intended to send time-tagged events to the station level (for example, operator
workplace) over the station bus. The events are there presented in an event list. The events can be
created from both internal logical signals and binary input channels. All the internal signals are
1158
SPA address CMD Input
4-S-4705
4-S-4706
4-S-4707
4-S-4708
4-S-4709
4-S-4710
4-S-4711
4-S-4712
4-S-4713
4-S-4714
4-S-4715
4-S-4716
4-S-4717
4-S-4718
4-S-4719
4-S-4720
shows an application example of how the user can, in a simplified way, connect the
SINGLECMD
BLOCK
^OUT1
^OUT2
^OUT3
^OUT4
^OUT5
INPUT1
^OUT6
INPUT2
^OUT7
INPUT3
^OUT8
INPUT4
^OUT9
^OUT10
^OUT11
^OUT12
^OUT13
^OUT14
^OUT15
^OUT16
SYNCH OK
breaker
SPA address CMD output
5-O-543
5-O-544
5-O-545
5-O-546
5-O-547
5-O-548
5-O-549
5-O-550
5-O-551
5-O-552
5-O-553
5-O-554
5-O-555
5-O-556
5-O-557
5-O-558
INPUT
AND
OUT
INPUT
NOUT
1MRK 502 066-UUS B
PULSETIMER
To output board, CLOSE
OUT
PULSETIMER
To output board, OPEN
OUT
IEC05000717-3-en.vsd
Technical manual
M11880-82 v4