CAUTION
Check to be sure all bystanders have cleared the area.
6. Press and hold the HEADER TILT EXTEND (B) button
on the ground speed lever (GSL).
• CALIBRATING TILT is displayed on the upper line.
• EXTEND TILT HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration.
HEADER TILT DONE will display on the lower
line once calibration is complete.
7. Release the HEADER TILT EXTEND (B) button.
• HEADER TILT SENSOR CAL is displayed on
upper line.
• PRESS RETRACT TILT is displayed on the
lower line.
8. Press and hold HEADER TILT RETRACT (D) button
on GSL.
• CALIBRATING TILT is displayed on the upper line.
• RETRACT TILT HOLD is displayed on the
lower line.
NOTE:
The word HOLD will flash during calibration.
HEADER TILT COMPLETE will display on the
lower line once calibration is complete.
9. Release HEADER TILT RETRACT (D) button.
• TO CALIBRATE SELECT is displayed on the
upper line.
• HEADER TILT is displayed on the lower line.
10. Press right arrow to select next header sensor
calibration or STOP & EXIT. Press SELECT.
Refer to
4.3.1 Calibrating the Header Height Sensor,
page 172
or
4.3.3 Calibrating the Header Float
Sensors, page
180.
11. Press PROGRAM to exit Programming Mode.
147962
CAB DISPLAY MODULE (CDM)
Figure 4.62: Header Tilt Controls on Ground
Speed Lever
Figure 4.63: Header Tilt Controls on Ground
Speed Lever
179
Revision A