Refitting the telescopic shaft
1
2
3
4
Product manual - IRB 365
3HAC079185-001 Revision: A
Action
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Move the conical connection over to the new
telescopic shaft axis 5.
Add Loctite 638 on the conical surfaces and Loc-
tite 243 on the threads
Refit the two telescopic shafts on the motor axis
4 and 5.
Tighten mounting clamping screws.
© Copyright 2022 ABB. All rights reserved.
4 Maintenance
4.3.2 Inspecting the telescopic shafts
Note
xx2100000760
Note
Tightening torque:
10 Nm
xx2100000751
xx2100000750
Tightening torque:
10 Nm