Required tools and equipment
Equipment
Standard toolkit
Pliers for parallel arms
Removing the upper arm
Use these procedures to remove the upper arm.
Preparations before removing the upper arm
1
2
3
Removing the lower arm
1
Product manual - IRB 365
3HAC079185-001 Revision: A
Article number
-
3HAC6194-1
Action
The robot does not need to be jogged into any
specific position due to repair activity.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
Remove any loads or tools attached to the tilt arm
on the head.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
© Copyright 2022 ABB. All rights reserved.
5.4.2 Replacing the upper arms
Note
Content is defined in sec-
tion
Standard toolkit on
page
228.
Used to push the parallel
arms apart.
Note
Note
Continues on next page
5 Repair
Continued
Image
xx0700000555