Concluding procedure
1
Product manual - IRB 365
3HAC079185-001 Revision: A
Action
Add Loctite 243 to all screws.
Fit the tilt stool to the tilt arm parts, and tighten
the attachment screws.
Add Loctite 243 to all screws.
Tighten the tilt arm part attachment screws.
Action
Calibrate the robot.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.5 Replacing the tilt arm
Continued
Note
xx2100000778
Tightening torque: 3.5 Nm.
xx2100000776
Tightening torque: 7 Nm.
xx2100000780
Note
See
Calibration information on
page
199.
Continues on next page