FRONT PANEL DESCRIPTION

12
12
13
14
C1 C2 H L HB
16
1
17
C
C
H
L
PV
3
PV
2
SV
2
SV
10
11
11
4
9
PV/SV
SEL
DATA
ENT
4
SV
PXZ-4
5
18
6
7
8
Model : PXZ4
Model : PXZ5
Name
Function
1 Process Value (PV) display
Displays the process value (PV).
2 Set value (SV) indication lamp Stays on while a set value is on the display.
3 Set value (SV) and
Set value (SV) or parameter symbols and codes
parameter display
are displayed when setting various parameters.
4 DOWN key
Decrements the numerical value in the place
(common for each digit)
selected with the UP key. Where various para-
meters are displayed, each parameter is dis-
played one by one every time this key is
pressed. The sequence of displays however, is
opposite to the sequence of displays with the
SEL key.
5 Direct SV key
By pressing this key, the set value (SV) is dis-
played.
6 SELECT key
The key to be used when switching over to the
1st or 2nd block parameters, or when scrolling
through the parameters within a block.
7 Data display key
Displays the data assigned to the parameter
selected with the SEL key
8 Data entry key
The key to be used for storing the data after pre-
vious data is changed. (none of changed data
can be registered unless this key is pressed.)
9 UP key for 1's place
By pressing once, the number in the units place
blinks. The number is continuously incremented
with the key held pressed.
10 UP key for 10's place
By pressing once, the number in the tens place
blinks. The number is continuously incremented
with the key held pressed.
11 Up key for 100's place
By pressing once, the number in the hundreds
place blinks. The number is continuously incre-
mented with the key held pressed. A numeric "9"
is followed by "0" and , concurrently, a number of
the thousands place is incremented by 1.
12 Control output indication lamp C (for PXZ4 only): Comes on when the control out-
put is ON.
C1: Comes on when the control output 1 is ON.
C2: Comes on when the control output 2 is ON.
13 Upper limit alarm
Comes on when the upper limit alarm is activated.
indication lamp (option)
14 Lower limit alarm
Comes on when the lower limit alarm is activated.
indication lamp
15 Heater break alarm
Comes on when the heater break alarm is output.
indication lamp
16 Process value (PV)/ set
Parameter symbols and codes are displayed
value (SV)/parameter display
for process value (PV) and set value (SV) and
(applicable to PXZ4 only)
when setting various parameters.
17 Process value (PV)
Stays on while process value (PV) is on display.
indication lamp
18 PV/SV SELECT key
The display of measured value (PV) and set value
(For PXZ4 only)
(SV) is toggled each time this key is pressed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
13
14
15
12
13
14
15
C
1
C
C1
C2
H
L
HB
2
3
PV
10
11
10
SV
9
4
9
SEL
DATA
7
SV
SEL
DATA
ENT
ENT
8
PXZ-7
PXZ-5
5
6
7
8
6
Model : PXZ7, 9

FRONT PANEL OPERATION

The PXZ controller programming menu consists of two blocks—
PRIMARY (SETPOINT) MENU and SECONDARY (SYSTEM) MENU. At
power up, the controller will be in the operational mode– process
variable (PV), in the case of PXZ4, and both process variable and set-
point variable (SV), in the case of PXZ-5, 7, 9 will be displayed. PV is
the variable that is being controlled, and it is not programmable.
When setting the parameters, turn off the power to the load (operat-
ing equipment) to ensure safety. Since it takes 30 minutes for the unit
to stabilize in terms of temperature, all measurements should be car-
ried out at least 30 minutes after the power is turned on. Option-relat-
ed features are displayed only when the options are provided.
Viewing and Setting Parameters
• After setting the data, press ENT key for registration.
• If the data setting is left as it is for 30 secs, the display is automati-
cally returned to the operational mode.
How to set Setpoint value (SV)
Operation
1. Power on
2. Press UP (units, tens or hundreds) – Digit blinks
key to select digit
3. Press the appropriate UP key or
the DOWN key to increment or
decrement digit value
4. Press ENT key
PRIMARY (SETPOINT) MENU
Operation
1. Operational mode
2. Press SEL key
3. Press DATA key
4. Press the appropriate UP key
once
5. Press the same UP key or the
DOWN key to increment or
decrement the data
6. Press ENT key
7. Press SEL key once to go to
the next parameter, or press
and hold UP (hundreds) key or
DOWN key to scroll down or up
the menu at a faster rate
8. Press SV (SV/PV for PXZ4) key
SECONDARY (SYSTEM) MENU
Operation
1. Operational mode
2. Press SEL key for about 3 secs
3. Press DATA key
4. Proceed as described before.
8
Display
– Operational mode
– SV value changes
– SV value registered
Display
– PV, SV
– "P" displayed
– "P" data displayed
– Corresponding digit blinks
– Data changes accordingly
– Data registered; "i" displayed
– "d" ....... "Mod"
– Operational mode
Display
– PV, SV
– "P-n1"
– "P-n1" data