Omega RD-MV100 Series User Manual page 107

Hide thumbs Also See for RD-MV100 Series:
Table of Contents

Advertisement

5.1 Voltage Input Setting
Explanation
5-2
The following table shows the mode, range, and measurable range.
Mode
Range
Volt
20 mV
60 mV
200 mV
2 V
6 V
20 V
DC current input
An external shunt resistor is connected to the input terminal to convert a current signal to
a voltage signal. The shunt resistors in the following table can be provided. A 250 Ω
shunt resistor, for example, is used to convert a 4 to 20 mA to a 1 to 5 V.
Name
Model (Part) Number
Shunt resistors
415920
(for screw terminals)
415921
415922
Shunt resistors
438920
(for clamped terminals)
438921
438922
Measurable Range
–20.00 to 20.00 mV
–60.00 to 60.00 mV
–200.0 to 200.0 mV
–2.000 to 2.000 V
–6.000 to 6.000 V
–20.00 to 20.00 V
Specification
250 Ω ±0.1%
100 Ω ±0.1%
10 Ω ±0.1%
250 Ω ±0.1%
100 Ω ±0.1%
10 Ω ±0.1%