11.11 Overview of the Report Function

Types of Reports and Specifications
11-22
This function is used to create hourly, daily, weekly, and monthly reports. The report
data can be displayed on the screen. The report data are saved to the external storage
medium in ASCII format. For data formats, see appendix 2, "Data Formats of ASCII
Files."
Types of reports
• Hourly report
On every hour on the hour, the average, maximum, minimum, and sum values of the
specified channels are determined from an hour of data up to the current hour and
written to the internal memory.
• Daily report
At the specified time everyday, the average, maximum, minimum, and sum values of
the specified channels are determined from a day of data up to the specified time and
written to the internal memory.
• Weekly report
At the specified time of the specified day every week, the average, maximum,
minimum, and sum values of the specified channels are determined from a week of
data up to the specified time and written to the internal memory.
• Monthly report
At the specified time of the specified date every month, the average, maximum,
minimum, and sum values of the specified channels are determined from a month of
data up to the specified time and written to the internal memory. The number days in
a month may be 28, 29, 30, or 31 days depending on the month.
Types of reports
• Hourly only : Creates reports every hour.
• Daily only : Creates reports every day.
• Daily and weekly : Creates daily and weekly reports.
• Daily and monthly : Creates daily and monthly reports.
For the report data display, see section 4.5.
Combinations of reports that can be created
The reports created by the RD-MV100 can be set to "hourly only," "daily only," "daily and
weekly," or "daily and monthly."
Number of measurement and computation channels that can be assigned to the
report
Up to 12 channels can be assigned to one report.
The report data are not created for channels that are set to [Skip] or those that have the
computation turned [Off].
About the sum unit (sum scale)
In the sum computation (TLOG.SUM) of time series, data are summed over the scan
interval. However, for flow values that have units /s, /min, /h, or /day a simple
summation results in the actual value not matching the computed result, because the
scan interval and the unit of the input values are different. In these cases, the unit of the
data measured over the scan interval is converted to match the unit of the input values
and the computation is performed.