2.6
Remote Control Wiring (/R1, Option)
Wiring Procedure
1.
2.
Terminal position
Terminal arrangement (only the position of the remote control terminals is
indicated.)
3.
Note
To prevent electric shock, ensure the main power supply is turned OFF.
Turn OFF the recorder and remove the cover for the option terminal.
Connect the remote control signal wires to the terminal.
The terminal arrangement for the remote control option is as follows. C is a
common terminal for terminals 1 through 8.
Replace the terminal cover and fasten it with screws.
The option terminal block itself can be removed by loosening the two screws at the top left
and bottom right of the terminal block. This makes wiring work easier. To prevent bad
contacts, make sure to securely tighten the screws after wiring.
Use shielded wires for the remote control wires to reduce the effects of noise. Connect the
shield to the earth ground terminal of the recorder.
WARNING
Option terminal
2
"C" denotes the
common terminal.
2-11