5.2 Thermocouple (TC)/Resistance Temperature Detector (RTD) Setting
Explanation
5-4
Confirming operation
To confirm the new settings, press the DISP/ENTER key.
To cancel the new settings, press the ESC key. A window appears for you to confirm the
cancellation. Select [Yes] using the arrow keys and press the DISP/ENTER key.
The following table shows the mode, range, and measurable range.
Mode
Range
Measurable Range
TC
R
0.0 to 1760.0°C
S
0.0 to 1760.0°C
B
0.0 to 1820.0°C
K
–200.0 to 1370.0°C
E
–200.0 to 800.0°C
J
–200.0 to 1100.0°C
.T
–200.0 to 400.0°C
N
0.0 to 1300.0°C
W
0.0 to 2315.0°C
L
–200.0 to 900.0°C
U
–200.0 to 400.0°C
RTD
Pt100
–200.0 to 600.0°C
JPt100
–200.0 to 550.0°C
CU1
–200.0 to 300.0°C
CU2
–200.0 to 300.0°C
CU3
–200.0 to 300.0°C
CU4
–200.0 to 300.0°C
CU5
–200.0 to 300.0°C
CU6
–200.0 to 300.0°C
CU25
–200.0 to 300.0°C
Cu1 to 6, and Cu25 are options.
For the setting procedure of the reference junction compensation and the burnout for the
thermocouple input, see section 5.9.
Note
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
ANSI, IEC584, DIN IEC584, JIS C1602-1981
Nicrosil-Nisil, IEC584, DIN IEC584
W-5%
Re/W-26% Re (Hoskins Mfg.Co.)
Fe-CuNi, DIN 43710
Cu-CuNi, DIN 43710
JIS C1604-1989, JIS C1606-1989, IEC751,
DIN IEC751
JIS C1604-1981, JIS C1606-1989
CU10 Ω GE
(Cuid based on a particular manufacturer)
CU10 Ω L&N
(Cuid based on a particular manufacturer)
CU10 Ω WEED
(Cuid based on a particular manufacturer)
CU10 Ω BAILAY
(Cuid based on a particular manufacturer)
CU10 Ω α = 0.00392 at 20°C
CU10 Ω α = 0.00393 at 20°C
CU25 Ω α = 0.00425 at 0°C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd-mv102Rd-mv104Rd-mv106Rd-mv112

Table of Contents