Omega RD-MV100 Series User Manual page 275

Hide thumbs Also See for RD-MV100 Series:
Table of Contents

Advertisement

Clamped Input Terminal (/H2) :
Clamped input terminal is used for input terminal.
Desk Top Type (/H5[ ]) :
Provides carrying handle and power cord when /H5D, /H5F/, H5R, or /H5J is specified.
Computation Functions (/M1) :
Can perfom computation, display the computed data assigned to channels in trends and
numerical values, and store computed data.
Channels assignable to computed data :
Operation :
Constant :
Digital input data via communication :
Remote input status :
Report functions :
14.6 Specifications of Optional Functions
RD-MV102, RD-MV104 : Up to 4 channels
RD-MV106, RD-MV112 : Up to 12 channels
General arithmetic operations :
Four arithmetic operations, square root, absolute,
common logarithm, exponential, power, relational
operations (<, ≤, >, ≥, =, ≠), logical operations
(AND, OR, NOT, XOR)
Statistical operations : Average, maximum, minimum and
summation
Special operations :
Rolling average
Available (Up to 12 constants)
Digital data via communication can be used in calculation
expression (Up to 12 data)
Remote input status (0/1) can be used in calculation
expression (Up to 8 inputs)
Report type : Hourly, daily, daily + monthly and daily +
weekly
Operation :
Average, maximum, minimum and summation
Data format : ASCII
14
14-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd-mv102Rd-mv104Rd-mv106Rd-mv112

Table of Contents