5. The usage condition of the display data storage area in the internal memory
This is displayed when display data acquisition is enabled.
• Bar graph
Displays the used space of the display data storage area.
• Time period
The remaining time for acquiring the display data. When the remaining time is
less than one hour, the time is displayed in units of minutes.
Remaining memory
Greater than or equal to 100 days
(Percentage of the remaining area with respect to the display data acquisition
area)
Greater than or equal to 100 hours, less than 100 days
(unit less than one day is rounded off)
Greater than or equal to 60 minutes, less than 100 hours : hours
(unit less than one hour is rounded off)
Less than 60 minutes
(unit less than one minute is rounded off)
• n/16
The maximum number of display data files* that can be written to the internal
memory is 16. "16" represents this value. "n" represents the number of files in the
internal memory.
* One file contains data that are acquired between start and stop operations.
Note
The display data are overwritten for the following cases. Be aware of these cases, because
data that are overwritten are lost.
When the display data storage area in the internal memory becomes full.
In such case, [Overwrite] is displayed in the status display section.
When the number of files that remains to be saved to the external medium exceeds 16.
6. The usage condition of the event data storage area in the internal memory
This is displayed when event data acquisition is enabled.
• When the trigger mode is set to [Free]
• Bar graph
Displays the used space of the event data storage area.
• Time period
The remaining time for acquiring the event data. When the remaining time is
less than one hour, the time is displayed in units of minutes.
Remaining memory
Greater than or equal to 100 days
Greater than or equal to 100 hours, less than 100 days
Greater than or equal to 60 minutes, less than 100 hours
Less than 60 minutes
• n/16
The maximum number of event data files* that can be written to the internal
memory is 16. "16" represents this value. "n" represents the number of files in
the internal memory.
* One file contains data that are acquired between start and stop operations.
Note
The event data are overwritten for the following cases. Be aware of these cases, because
data that are overwritten are lost.
When the event data storage area in the internal memory becomes full.
In such case, [Overwrite] is displayed in the status display section.
When the number of files that remains to be saved to the external medium exceeds 16.
4.2 Explanation of the Status Display Section
Unit
: %
: days
: minutes
Unit (refer to item 5)
: %
: days
: hours
: minutes
4