FlexTest SE Controllers
Specifications
28
Introduction
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
FlexTest SE Specifications
P
ARAMETER
Environmental
Temperature
Relative humidity
Altitude
Power input
*
Input voltage
Input frequency
Input surge
Insulation over
voltage
Pollution degree
Weight
* The specification shown conforms to CE Low Voltage Directive
requirements. The specification allows for 10% of the values
stated. The actual voltage the 493.02 chassis can operate is
90–264 V AC.
S
PECIFICATION
For indoor use only
5ºC – 40ºC (41ºF – 104ºF)
10% – 85%, noncondensing
For use at altitudes up to 2000 m
(6500 ft)
power factor corrected universal input
100 – 240 V AC
47 – 63 Hz
<50 A
Category I
2
approximately 8.6 kg (19 lb)
MTS 793 Controller Hardware
Need help?
Do you have a question about the FlexTest IIm and is the answer not in the manual?