No.
Parameter Adjustment
1
Destination
Destination address
(Address)
2
Destination
Destination level
(Level)
3
Source
Source address
(Address)
4
Source
Source level
(Level)
3
Press [Execute].
Deleting Wiring Settings
1
In the Engineering Setup >Router/Tally >Wiring
menu (7363), select the wiring.
2
Press [Delete].
Sorting Wiring Settings
In the Engineering Setup >Router/Tally >Wiring menu
(7363), press [Sort].
The sorting of wiring settings is executed in the following
sequence.
Destination level order (ascending) t Destination
address order (ascending) t Source level order
(ascending)
Tally Generation Settings
Specify the destination to be the reference for tally
generation, and configure the settings.
The settings used are common to both parallel and serial
tallies.
Configuring Tally Generation
1
In the Engineering Setup >Router/Tally >Tally Enable
menu (7364), press [New].
The New menu (7364.1) appears.
2
Set the following parameters.
No.
Parameter Adjustment
1
Destination
Address
2
Destination
Level
3
Tally Type
a) 1: R1, 2: G1, 3: R2, 4: G2, 5: R3, 6: G3, 7: R4, 8: G4, 9: R5, 10: G5,
11: R6, 12: G6, 13: R7, 14: G7, 15: R8, 16: G8 (R stands for Red
Tally, and G for Green Tally)
3
In the <Tally Enable> group, specify the tally
generation mode.
Enable: Always generate a tally.
Disable: Never generate a tally.
Tally Input: Generate a tally from the tally input state.
4
When [Tally Input] is selected in step 3, select one of
the following in the <Tally Input> group.
DCU1: Generate tally with reference to signal that is
input on the SIU1 (DCU function) port.
DCU2: Generate tally with reference to signal that is
input on the SIU2 (DCU function) port.
Select the tally input port number using the following
parameter.
No.
Parameter Adjustment
5
Input Port
5
Press [Execute].
Modifying Tally Generation
1
In the Engineering Setup >Router/Tally >Tally Enable
menu (7364), press [Modify].
474
Destination address
Destination level
a)
Tally type
Tally input port number