a) This shows one of Local Target, Local Source, Global
Target, and Global Source.
b) This shows one of Loc XYZ, Loc Size, Rot, Spin, Axis Loc,
Skew, Asp, and Pers.
To display a detailed list of three-dimensional
parameters
In the DME menu, press the menu title button (the [DME]
in the upper left part of the screen).
The DME >Status menu (4100) appears.
The three-dimensional parameters for the DME reference
channel currently selected in the device control block are
displayed.
Display on the device control block
The following information appears on the display of the
device control block (trackball).
• Reference channel name: DME1 to DME4
• Currently selected three-dimensional space: LOCAL/
GLB and SRC/TRGT
• Currently selected parameter item: LOC XYZ, ASP
PERS, LOC SIZE, ROT, AXIS LOC, SPIN, SKEW
• Parameter setting values
Reference channel name
Selected parameter item name
Selected three-dimensional space

Three-Dimensional Parameter Entry

In addition to setting three-dimensional parameter values
using the trackball and Z-ring, you can enter numeric
values directly from the numeric keypad control block.
Entering three-dimensional parameter
Type of three-
values
a)
dimensional space
1
Three-dimensional
transform operation
b)
mode
Value of X
2
Value of Y
Value of Z
3
To enter a difference value
Press the [+/−] button and enter a difference from the
current value, and press the [TRIM] button to confirm.
Each time you press the [+/−] button, it toggles between
plus (+) and minus (–).
Resetting three-dimensional parameters
To set the current three-dimensional parameter values to
the closest detent points (see page 211), press the [CTR]
button once in the device control block.
To reset three-dimensional parameter values to the default
values (see page 211) for the currently selected transform
operation mode, press the [CTR] button twice in rapid
succession.
Returning three-dimensional parameters
to default state (clear work buffer)
Value on X-axis
To clear and reset to default state only the three-
dimensional transform parameters contained in the work
buffer, depending on the DME operation, press the [CLR
WORK BUFR] button once in the device control block.
To clear all parameters in the work buffer and return the
DME to the default state, press the [CLR WORK BUFR]
button twice in rapid succession.
It is necessary to do this for both the local space and global
Value on Z-axis
space.
For the DME default state, you can select either the factory
Value on Y-axis
default settings or user settings.
For details, see "Power-On (Startup) State Selection"
(page 391).
224
In the device control block, press the [X], [Y], or [Z]
button, turning it on.
The parameter item and setting value appears on the
numeric keypad control block display.
Enter a parameter value using the numeric keypad
buttons on the numeric keypad control block.
The number of significant digits after the decimal
point is four.
Press the [ENTER] button.
The parameter value is changed, and the image
changes.