Copying Data Between
Control Panels
You can copy data for the following registers at the same
time between control panels
• Shotbox
• Master timeline
• Master snapshot
• Macro
• Macro timeline
• Menu macro
Notes
• Copying is possible only from a control panel that has a
different unit ID than the menu panel to a target control
panel that has the same unit ID as the menu panel.
• Before data is copied, the existing register data in the
copy destination is deleted.
Copying register data
1
Open the Copy/Swap >Panel Data Copy menu (3131).
2
Select the copy source control panel in the list on the
right and the copy destination control panel in the list
on the left.
3
Press [T Copy].
4
Check the message, then press [Yes].

Misc Menu

In the Misc menu, you can carry out the following
operations.
• Set the DME override function.
• Enable or disable operations from Virtual Shot Box/
Virtual Menu.
• Enable or disable side flags on the background bus of
each bank.
For details about side flags, see "Side Flags"
(page 194).
• Enable or disable the safe title for each switcher output.
• Display the transition rate, independent key transition
rate, and fade-to-black transition rate for each bank, and
change the settings.
• Set the AUX mix transition rate.
Setting DME Override (DME Forced
Select Mode)
1
Open the Misc >Enable >Port Enable menu (3211).
2
In the <DME Override> group, select the DME
override operation mode.
DME Override: When a switcher snapshot or effect
using a DME is recalled, forcibly select the DME
that was used when saving.
On Air Protect: The operation is the same as the
DME override function, except that a DME being
used by an M/E bank or P/P bank that is on air will
not be forcibly selected.
Note
If effects using the same DME channel are recalled
simultaneously in two or more regions, the DME is
selected with the order of precedence PGM/PST >M/
E-1 >M/E-2 >M/E-3 >M/E-4 >M/E-5.
Configuring Virtual Shot Box/Virtual
Menu
You can control switcher operations from a Virtual Shot
Box or Virtual Menu connected to the control panel.
Operation can also be disabled when you want to inhibit
operations from Virtual Shot Box or Virtual Menu.