Settings Relating To Device Connections; Setting The Control Mode For P-Bus Devices; Assigning The Target Port To A Channel Selection Button - Sony XVS-9000 User Manual

Multi format switcher system
Hide thumbs Also See for XVS-9000:
Table of Contents

Advertisement

2
Press [Name].
3
Enter a name of up to 8 characters in the keyboard
window, and press [Enter].
Settings Relating to
Device Connections
Setting the Control Mode for P-Bus
Devices
In the <P-Bus Control> group of the Engineering Setup
>Panel >Device Interface menu (7325), select the protocol
mode.
Trigger: When a predetermined button is pressed, the
action command assigned to that button is output to
control an external device.
Timeline: The external device is controlled as a keyframe
effect controlled by the control panel.
Assigning the Target Port to a
Channel Selection Button
You can assign an SIU serial port or a network port to the
channel selection buttons (CH1 to CH12).
This allows you to operate a device connected to the port
using the specified channel selection button.
For details about port settings, see "Configuring the
Connection Port of External Devices" (page 466).
1
In the Engineering Setup >Panel >Device Interface
menu (7325), press [Device Assign].
The Device Assign menu (7325.4) appears.
2
In the status area, select the target port to set.
3
In the <Assign> group, select the button (DEV CH1 to
DEV CH12) to which to assign the port.
[DEV CH1] to [DEV CH12] correspond to the [CH1]
to [CH12] channel selection buttons on the device
control block.
Notes
• It is not possible to assign the same port to more than
one button. The most recently set button is enabled.
• A port configured with a P-Bus compatible device
cannot be assigned to a button.
4
Repeat steps 2 and 3 as required to set other ports.
419