Settings Relating to
System Configuration

Selecting the Operation Mode

You can set the system operation mode (Single Proc or
Dual Simul).
In Dual Simul mode, the target system must be selected in
order to set up the two switchers and DMEs.
1
In the <Operation Mode> group of the Engineering
Setup >System >System Config menu (7312), select
the operation mode.
Single Proc: The control panel controls a single
switcher and DMEs.
Dual Simul: The control panel controls two switchers
and DMEs simultaneously. This allows operation
to continue on one switcher if the other switcher
cannot communicate due to device failure or other
cause.
When [Dual Simul] is selected, select [System1] or
[System2] in the <Setup Target> group. You can also
select both systems and configure them
simultaneously.
To clear the setting
Press [Clear].
2
Press [Execute].
3
Check the message, then press [Yes].
Specifying the Switcher Controlled
by the Control Panel
1
In the status area of the Engineering Setup >System
>System Config menu (7312), select the target control
panel to set.
2
Specify the switcher to control.
If there is only one switcher on the network: In the
<1st Switcher> group, select [SWR1] or [SWR2].
In the <2nd Switcher> group, disable both
[SWR1] and [SWR2].
If there are two switchers on the same network: In
the <1st Switcher> group and <2nd Switcher>
group, select the switchers.
When the operation mode is set to [Dual Simul],
the status of the switcher set in the <1st Switcher>
group appears on the control panel.
3
To set the selected control panel as the tally control
master panel, press [Tally Master], turning it on.
If there are multiple control panels and switchers, the
control panel on which [Tally Master] is enabled
performs tally control for the whole system.
Notes
• When there are multiple control panels, make sure
that one of them has [Tally Master] enabled.
• If the master panel is changed, be sure to copy and
save the setup tally (TLY) and router (RTR) data in
the File menu, and make the same settings on
another panel.
• If the master panel tally data is loaded into a panel
with a different unit ID, then [Tally Master] is
disabled.
• [Tally Master] cannot be enabled on the 4th control
panel (PNL4).
To clear the switcher and master panel settings
Press [Clear].
4
Press [Execute].
5
Check the message, then press [Yes].
Specifying the DME Used on the
Switcher
1
In the Engineering Setup >System >System Config
menu (7312), specify the DME to use.
When selecting a DME on SWR1: Select [DME1] in
the <SWR1> group.
When selecting a DME on SWR2: Select [DME3] in
the <SWR2> group.
2
Press [Execute].
3
Check the message, then press [Yes].
388