Wiring Settings

When configuring a system in which the switcher inputs
and outputs are connected to a router, setting this
connection configuration (referred to as "wiring") in the S-
Bus space, or inputting the information which specifies the
physical wiring, is necessary.
The settings are common to the parallel and serial tallies.

Making New Wiring Settings

1
Open the Engineering Setup >Router/Tally >Wiring
>New menu (7363.1).
2
Set the destination.
When switcher inputs and outputs are connected to the
router in a group, you can specify the start and end
destination addresses.
Destination From: Specifies the start destination
address for the wiring configuration.
Destination To: When the wiring configuration is
multiple, specifies the end destination address. For
a single wiring connection, this setting is not
required.
Destination Level: Specifies the destination level of
the wiring configuration.
No.
Parameter
1
Destination
(From)
2
Destination
(To)
3
Destination
(Level)
3
Set the source.
Source From: Specifies the source start address for
the wiring configuration.
Source Level: Specifies the source level for the wiring
configuration.
No.
Parameter
4
Source
(From)
5
Source
(Level)
4
Press [Execute].
258
Wiring Settings / Tally Generation Settings
Adjustment
Destination start address
Destination end address
Destination level
Adjustment
Source start address
Source level

Changing Wiring Settings

1
Open the Engineering Setup >Router/Tally >Wiring
>Modify menu (7363.2).
2
Referring to steps 2 and 3 in the preceding section
"Making New Wiring Settings" (1 p. 258)
the parameters as required. In this case, however, it is
not possible to specify multiple destinations in a single
operation, and a single address in "Destination
Address" must be specified.
3
Press [Execute].

Deleting Wiring Settings

1
In the Engineering Setup >Router/Tally >Wiring
menu (7363), select the wiring.
2
Press [Delete].

Sorting Wiring Settings

In the Engineering Setup >Router/Tally >Wiring menu
(7363), press [Sort].
The sorting of wiring settings are executed in the following
order.
Destination level order (ascending) t Destination
address order (ascending) t Source level order
(ascending)

Tally Generation Settings

You specify the destination to be the reference for tally
generation, and make various settings.
The settings are common to the parallel and serial tallies.
Making New Tally Generation
Settings
1
Open the Engineering Setup >Router/Tally >Tally
Enable >New menu (7364.1).
2
Set the following parameters.
No.
Parameter
Adjustment
1
Destination
Destination address
Address
change